N2 - Endosseous oral implants are used for orthodontic anchorage in subjects with multiple tooth agenesis. Their effectiveness under orthodontic loading has been demonstrated clinically and experimentally. This study examines three-dimensional (3D) finite element (FE) models for bone and implants. A numerical simulation of stress distributions around implants was used to determine the best length, diameter, screw type, screw pitch, and screw head for implants to dissipate stress. The model was applied to determine the pattern and distribution of stresses within the endosseous implant and on supporting tissues when the endosseous implant is used for orthodontic anchorage. A threaded implant was placed in an edentulous segment of a human mandible with cortical and cancellous bone. Analytical results demonstrate that maximum stresses were always located around the implant neck in marginal bone. Thus, this area should be preserved clinically to maintain the structure and function of a bone implant.
AB - Endosseous oral implants are used for orthodontic anchorage in subjects with multiple tooth agenesis. Their effectiveness under orthodontic loading has been demonstrated clinically and experimentally. This study examines three-dimensional (3D) finite element (FE) models for bone and implants. A numerical simulation of stress distributions around implants was used to determine the best length, diameter, screw type, screw pitch, and screw head for implants to dissipate stress. The model was applied to determine the pattern and distribution of stresses within the endosseous implant and on supporting tissues when the endosseous implant is used for orthodontic anchorage. A threaded implant was placed in an edentulous segment of a human mandible with cortical and cancellous bone. Analytical results demonstrate that maximum stresses were always located around the implant neck in marginal bone. Thus, this area should be preserved clinically to maintain the structure and function of a bone implant.
KW - 3D finite element analysis
KW - Style of implant
KW - Von Mises stress
UR - http://www.scopus.com/inward/record.url?scp=84951289489&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84951289489&partnerID=8YFLogxK
M3 - Article
AN - SCOPUS:84951289489
SN - 0257-9731
VL - 35
SP - 389
EP - 395
JO - Journal of the Chinese Society of Mechanical Engineers, Transactions of the Chinese Institute of Engineers, Series C/Chung-Kuo Chi Hsueh Kung Ch'eng Hsuebo Pao
JF - Journal of the Chinese Society of Mechanical Engineers, Transactions of the Chinese Institute of Engineers, Series C/Chung-Kuo Chi Hsueh Kung Ch'eng Hsuebo Pao
IS - 5
ER -