TY - JOUR
T1 - Stability of blood biochemistry levels in animal model research
T2 - Effects of storage condition and time
AU - Peng, Tai C.
AU - Hsu, Bang G.
AU - Yang, Fwu L.
AU - Chao, Yf
AU - Harn, Horng J.
AU - Lee, Ru Ping
N1 - Copyright:
Copyright 2010 Elsevier B.V., All rights reserved.
PY - 2010/4
Y1 - 2010/4
N2 - The purpose of this study was to compare whole blood and plasma in terms of the subsequent accuracy of blood lactate, glucose, lactate dehydrogenase (LDH), creatine phosphokinase (CPK), aspartate aminotransferase (AST), and alanine aminotransferase (ALT) measurement. Blood samples were drawn from 8 male Wistar-Kyoto rats. The rats were homologous, weighed 300-380 g, were housed in the same environment, and were provided with food and water under the same conditions. Blood draws occurred in all rats at same time. The blood specimens were divided into two samples, one to be stored as whole blood (WBS) and one to be stored as plasma (PS). All the blood sample analyses were performed by trained and experienced personnel to ensure that differences in results were due to variation in form in which specimens were stored rather than to technique. The lactate concentration in the WBS group gradually increased over time, intraclass correlation coefficient (ICC) = 0.541, 95% confidence interval (CI; -0.197, 0.893), and was higher than that of the PS group, ICC = 0.897, 95% CI (0.733, 0.976). By contrast, glucose level gradually declined for the WBS group, ICC= -0.367, 95% CI (-2.563, 0.682). Whole blood storage increased measurement variation for lactate, glucose, LDH, and CPK. Plasma storage prolonged the stability of the biochemical components. This study demonstrates the importance of evaluating validity at each stage of developing and testing animal models.
AB - The purpose of this study was to compare whole blood and plasma in terms of the subsequent accuracy of blood lactate, glucose, lactate dehydrogenase (LDH), creatine phosphokinase (CPK), aspartate aminotransferase (AST), and alanine aminotransferase (ALT) measurement. Blood samples were drawn from 8 male Wistar-Kyoto rats. The rats were homologous, weighed 300-380 g, were housed in the same environment, and were provided with food and water under the same conditions. Blood draws occurred in all rats at same time. The blood specimens were divided into two samples, one to be stored as whole blood (WBS) and one to be stored as plasma (PS). All the blood sample analyses were performed by trained and experienced personnel to ensure that differences in results were due to variation in form in which specimens were stored rather than to technique. The lactate concentration in the WBS group gradually increased over time, intraclass correlation coefficient (ICC) = 0.541, 95% confidence interval (CI; -0.197, 0.893), and was higher than that of the PS group, ICC = 0.897, 95% CI (0.733, 0.976). By contrast, glucose level gradually declined for the WBS group, ICC= -0.367, 95% CI (-2.563, 0.682). Whole blood storage increased measurement variation for lactate, glucose, LDH, and CPK. Plasma storage prolonged the stability of the biochemical components. This study demonstrates the importance of evaluating validity at each stage of developing and testing animal models.
KW - Animal model
KW - Glucose
KW - Lactate
KW - Measurement stability
KW - Storage condition
KW - Whole blood
UR - http://www.scopus.com/inward/record.url?scp=77949869460&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=77949869460&partnerID=8YFLogxK
U2 - 10.1177/1099800409350771
DO - 10.1177/1099800409350771
M3 - Article
C2 - 20028688
AN - SCOPUS:77949869460
SN - 1099-8004
VL - 11
SP - 395
EP - 400
JO - Biological Research for Nursing
JF - Biological Research for Nursing
IS - 4
ER -