TY - JOUR
T1 - Sensitive, color-indicating and labeling-free multi-detection cholesteric liquid crystal biosensing chips for detecting albumin
AU - Wang, I. Te
AU - Lee, Yen Hua
AU - Chuang, Er Yuan
AU - Hsiao, Yu Cheng
N1 - Funding Information:
Funding: This work was financially supported by the Ministry of Science and Technology (MOST), Taiwan, under grant no. MOST 109-2636-E-038-001, 108-2221-E-038-017-MY3, 108-2320-B-038-061-MY3; Taipei Medical University Hospital grant (109TMU-TMUH-02).
Publisher Copyright:
© 2021 by the authors. Licensee MDPI, Basel, Switzerland.
PY - 2021
Y1 - 2021
N2 - A novel device for cholesteric liquid crystal (CLC)-based microfluidic chips, accommodated in a polydimethylsiloxane material, was invented. In this device, the reorientation of the CLCs was consistently influenced by the surface of the four channel walls and adjacent CLCs. When the inside of the microchannel was coated with the alignment layer, the CLCs oriented homeotropically in a focal conic state under cross-polarizers. Once antigens had bound onto antibodies immobilized onto the orientation sheet-coated channel walls, the light intensity of the CLC molecules converted from a focal conic state to a bright planar state caused by disrupting the CLCs. By means of utilizing pressure-propelling flow, the attachment of antigen/antibody to the CLCs should be detectable within consecutive sequences. The multi-microfluidic CLC-based chips were verified by measuring bovine serum albumin (BSA) and immune complexes of pairs of BSA antigen/antibody. We showed that the multiple microfluidic immunoassaying can be used for measuring BSA and pairs of antigen/ antibody BSA with a detection limit of about 1 ng/mL. The linear range is 0.1 g/mL-1 mg/mL. A limit of immune detection of pairs of BSA antigens/antibodies was 10 ng/mL of BSA plus 1000 ng/mL of the anti-BSA antibodies was observed. According to this innovative creation of immunoassaying, an unsophisticated multi-detection device with CLC-based labeling-free microfluidic chips is presented.
AB - A novel device for cholesteric liquid crystal (CLC)-based microfluidic chips, accommodated in a polydimethylsiloxane material, was invented. In this device, the reorientation of the CLCs was consistently influenced by the surface of the four channel walls and adjacent CLCs. When the inside of the microchannel was coated with the alignment layer, the CLCs oriented homeotropically in a focal conic state under cross-polarizers. Once antigens had bound onto antibodies immobilized onto the orientation sheet-coated channel walls, the light intensity of the CLC molecules converted from a focal conic state to a bright planar state caused by disrupting the CLCs. By means of utilizing pressure-propelling flow, the attachment of antigen/antibody to the CLCs should be detectable within consecutive sequences. The multi-microfluidic CLC-based chips were verified by measuring bovine serum albumin (BSA) and immune complexes of pairs of BSA antigen/antibody. We showed that the multiple microfluidic immunoassaying can be used for measuring BSA and pairs of antigen/ antibody BSA with a detection limit of about 1 ng/mL. The linear range is 0.1 g/mL-1 mg/mL. A limit of immune detection of pairs of BSA antigens/antibodies was 10 ng/mL of BSA plus 1000 ng/mL of the anti-BSA antibodies was observed. According to this innovative creation of immunoassaying, an unsophisticated multi-detection device with CLC-based labeling-free microfluidic chips is presented.
KW - BSA
KW - Cholesteric liquid crystal
KW - Microfluidic chip
UR - http://www.scopus.com/inward/record.url?scp=85105554296&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85105554296&partnerID=8YFLogxK
U2 - 10.3390/polym13091463
DO - 10.3390/polym13091463
M3 - Article
AN - SCOPUS:85105554296
SN - 2073-4360
VL - 13
JO - Polymers
JF - Polymers
IS - 9
M1 - 1463
ER -