TY - JOUR
T1 - Real-time streaming of surgery performance and intraoperative imaging data in the hybrid operating room
T2 - Development and usability study
AU - Lin, Chun Cheng
AU - Chen, Yu Pin
AU - Chiang, Chao Ching
AU - Chang, Ming Chau
AU - Lee, Oscar Kuang Sheng
N1 - Funding Information:
The authors acknowledge financial support from the corporate funding (Advantech Co, Ltd) of Yang-Ming University Collaboration Projects (Grant Number: YM105C042), and Taipei Veterans General Hospital (V107B-003), Taiwan. The authors also acknowledge the faculty of the Department of Orthopaedic Surgery, Yuanlin Christian Hospital for their contribution to the research.
Publisher Copyright:
© 2020 Chun-Cheng Lin, Yu-Pin Chen, Chao-Ching Chiang, Ming-Chau Chang, Oscar Kuang-Sheng Lee.
PY - 2020/4
Y1 - 2020/4
N2 - Background: The trend of quick evolution and increased digital data in today's operating rooms (ORs) has led to the construction of hybrid ORs. There is often a main control room with monitors for integrating intraoperative data from multiple devices in the hybrid OR. However, there is no adequate solution for communicating the data with people outside the OR. Objective: The objective of this study was to design an intelligent operating room (iOR) system, augmented onto the existing information technology (IT) infrastructure of hybrid ORs, to stream surgery performance and intraoperative imaging data. Methods: In this study, an all-in-one device with synergetic encoder and decoder was used. The device was able to stream multiple sources to one display. The lossless video and images from specific surgical workflows were streamed outside the hybrid OR through network protocols and were further managed by a streaming server and wireless control system. The steps of this study included the following: (1) defining the requirements and feasibility of an iOR system in the hybrid OR, (2) connecting multiple sources, (3) setting up equipment across the hybrid OR and a conference room, (4) designing a video management system, and (5) real-time streaming under specific surgical workflows. Results: The wired streamed video was shown simultaneously on the display in the hybrid OR and the display in the conference room with near-zero latency. Additionally, an interactive video between the hybrid OR and the conference room was achieved through the bidirectional wireless control system. The functions of recording, archiving, and playback were successfully provided by the streaming server. The readily available hardware components and open-access programming reduced the cost required to construct this streaming system. Conclusions: This flexible and cost-effective iOR system not only provided educational benefits, but also contributed to surgical telementoring.
AB - Background: The trend of quick evolution and increased digital data in today's operating rooms (ORs) has led to the construction of hybrid ORs. There is often a main control room with monitors for integrating intraoperative data from multiple devices in the hybrid OR. However, there is no adequate solution for communicating the data with people outside the OR. Objective: The objective of this study was to design an intelligent operating room (iOR) system, augmented onto the existing information technology (IT) infrastructure of hybrid ORs, to stream surgery performance and intraoperative imaging data. Methods: In this study, an all-in-one device with synergetic encoder and decoder was used. The device was able to stream multiple sources to one display. The lossless video and images from specific surgical workflows were streamed outside the hybrid OR through network protocols and were further managed by a streaming server and wireless control system. The steps of this study included the following: (1) defining the requirements and feasibility of an iOR system in the hybrid OR, (2) connecting multiple sources, (3) setting up equipment across the hybrid OR and a conference room, (4) designing a video management system, and (5) real-time streaming under specific surgical workflows. Results: The wired streamed video was shown simultaneously on the display in the hybrid OR and the display in the conference room with near-zero latency. Additionally, an interactive video between the hybrid OR and the conference room was achieved through the bidirectional wireless control system. The functions of recording, archiving, and playback were successfully provided by the streaming server. The readily available hardware components and open-access programming reduced the cost required to construct this streaming system. Conclusions: This flexible and cost-effective iOR system not only provided educational benefits, but also contributed to surgical telementoring.
KW - Encoder and decoder
KW - Hybrid operating room
KW - Information technology
KW - Information technology infrastructure
KW - Medical imaging
KW - Operating room
KW - Real-time streaming
KW - Real-world evidence
KW - Surgery
KW - Surgical telementoring
UR - http://www.scopus.com/inward/record.url?scp=85097465287&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85097465287&partnerID=8YFLogxK
U2 - 10.2196/18094
DO - 10.2196/18094
M3 - Article
AN - SCOPUS:85097465287
SN - 2291-9694
VL - 8
JO - JMIR Medical Informatics
JF - JMIR Medical Informatics
IS - 4
M1 - e18094
ER -