T1 - New concepts - Biomechanical studies of a newly designed femoral prosthesis (cervico-trochanter prosthesis)
AU - Shih, Chun Hsiung
AU - Chen, Weng Pin
AU - Tai, Ching Lung
AU - Kuo, Rong Fu
AU - Wu, Chi Chuan
AU - Chen, Chih Hwa
PY - 1997/10
Y1 - 1997/10
N2 - Objective. A newly designed stemless (cervico-trochanter) prosthesis was developed for the purpose of reducing the incidence of the stress-shielding effect caused by the traditional stem-type prosthesis. Design. Both mechanical test and three-dimensional finite element analysis were performed for comparing the differences of strain and stress distributions between the intact, C-T and PCA prosthetic femora. Background. The stress-shielding effect and polyethylene (PE) wear debris were thought to be the main factors that resulted in local bone loss after the implantation of stem-type prostheses. In this study, we developed the new C-T prosthesis, which aimed to resolve the above-mentioned problems. Methods. Six pairs of femora taken from human male cadavers were used to compare the strain magnitudes of intact (n = 12), C-T (n = 12) and PCA (n = 4) prosthetic femora in specific positions. Failure load tests of C-T (n = 8) and PCA (n = 12) prosthetic femora were also carried out from the load-displacement curve. The analysis of variance (ANOVA) test was used for statistical analysis. In addition, three-dimensional finite element stress analyses were performed using a commercial package, ANSYS, on a Convex 3810 computer. Results. Both mechanical test and finite element results showed that the C-T prosthetic femora has a lower stress-shielding tendency than the PCA prosthetic femora (P < 0.001). The C-T prosthetic femora also withstood an average bearing load of 6312 N, which is greater than that of the PCA prosthesis at 5358 N (P < 0.01). Conclusions. The C-T prosthetic femur could withstand a higher failure load than the PCA prosthesis, which effectively reduced the incidence of the stress-shielding effect. Moreover, the particular design of the C-T prosthesis also reduced localized osteolysis because of the overall coverage of the neck-trochanteric area.
AB - Objective. A newly designed stemless (cervico-trochanter) prosthesis was developed for the purpose of reducing the incidence of the stress-shielding effect caused by the traditional stem-type prosthesis. Design. Both mechanical test and three-dimensional finite element analysis were performed for comparing the differences of strain and stress distributions between the intact, C-T and PCA prosthetic femora. Background. The stress-shielding effect and polyethylene (PE) wear debris were thought to be the main factors that resulted in local bone loss after the implantation of stem-type prostheses. In this study, we developed the new C-T prosthesis, which aimed to resolve the above-mentioned problems. Methods. Six pairs of femora taken from human male cadavers were used to compare the strain magnitudes of intact (n = 12), C-T (n = 12) and PCA (n = 4) prosthetic femora in specific positions. Failure load tests of C-T (n = 8) and PCA (n = 12) prosthetic femora were also carried out from the load-displacement curve. The analysis of variance (ANOVA) test was used for statistical analysis. In addition, three-dimensional finite element stress analyses were performed using a commercial package, ANSYS, on a Convex 3810 computer. Results. Both mechanical test and finite element results showed that the C-T prosthetic femora has a lower stress-shielding tendency than the PCA prosthetic femora (P < 0.001). The C-T prosthetic femora also withstood an average bearing load of 6312 N, which is greater than that of the PCA prosthesis at 5358 N (P < 0.01). Conclusions. The C-T prosthetic femur could withstand a higher failure load than the PCA prosthesis, which effectively reduced the incidence of the stress-shielding effect. Moreover, the particular design of the C-T prosthesis also reduced localized osteolysis because of the overall coverage of the neck-trochanteric area.
KW - Finite element analysis
KW - Proximal femoral strains
KW - Stemless prosthesis
KW - Stress shielding
UR - http://www.scopus.com/inward/record.url?scp=0031255004&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0031255004&partnerID=8YFLogxK
U2 - 10.1016/S0268-0033(97)00032-6
DO - 10.1016/S0268-0033(97)00032-6
M3 - Article
AN - SCOPUS:0031255004
SN - 0268-0033
VL - 12
SP - 482
EP - 490
JO - Clinical Biomechanics
JF - Clinical Biomechanics
IS - 7-8
ER -