摘要
In this study, DNA sequencing droplet trajectories are observed and analyzed using an application-specific integrated circuit system and a micro-electromechanical system structure jetting chip. We investigate a droplet jetting technique and apply it to biomedical test chips. This use of a sprayed chip structure can reduce sequencing time by two-thirds compared with traditional methods. The structure is a three-dimensional, multi-channel drive system that can control droplets more precisely. The circuit's input control signal was generated and placed on a chip based on the quantitative design of liquid droplets. Delay time and frequency were used to set the LED light sources. In this study, we would use frequencies of 4 kHz, 8 kHz, and 12 kHz combined with two groups of different orifices and frequencies for ink droplet outlet velocity.
原文 | 英語 |
---|---|
頁(從 - 到) | 243-250 |
頁數 | 8 |
期刊 | Microelectronics Reliability |
卷 | 91 |
DOIs | |
出版狀態 | 已發佈 - 12月 1 2018 |
ASJC Scopus subject areas
- 電子、光磁材料
- 原子與分子物理與光學
- 安全、風險、可靠性和品質
- 凝聚態物理學
- 表面、塗料和薄膜
- 電氣與電子工程