False-positive fluorine-18 fluorodeoxy-D-glucose positron emission tomography imaging caused by retained gauze in a woman with recurrent ovarian cancer: A case report

M. Y. Chen, K. K. Ng, S. Y. Ma, T. I. Wu, T. C. Chang, C. H. Lai

研究成果: 雜誌貢獻文章同行評審

7 引文 斯高帕斯(Scopus)

摘要

We report a case of a 47-year-old woman with a false-positive [ 18F]fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) result caused by retained gauze during resection of liver metastasis for a Stage IV ovarian cancer at primary cytoreductive surgery. She achieved complete remission and remained free of progression for seven years. Owing to elevation of CA-125, computed tomography and PET studies were performed, and both showed two potentially resectable lesions. One was located ventral to the diaphragmatic surface of the left hepatic lobe and the other was around the gauze at the right hepatorenal fossa. During surgical intervention, the left supraheptic tumor was excised and the gauze with surrounding granulation was removed. However, the former proved to be recurrent ovarian cancer with the latter proven false-positive. This case demonstrates that PET results should be interpreted with caution in differentiating a benign inflammatory process from malignant abnormalities, especially in regions with a high probability of granulomatous lesions.