TY - JOUR
T1 - External quality assessment of sputum smear microscopy in taiwan
AU - Wu, M. H.
AU - Chiang, C. Y.
AU - Jou, R.
AU - Chang, S. Y.
AU - Luh, K. T.
PY - 2009
Y1 - 2009
N2 - OBJECTIVE: To evaluate the quality of sputum smear microscopy in nine Taiwan Centers for Disease Control contract laboratories, an external quality assessment (EQA) programme has been implemented since 2005. DESIGN: A sampling strategy based on the lot quality assurance system was applied to select slides for rechecking. Supervisory visits and technical training were conducted to determine the causes of errors and to take corrective action. RESULTS: Of the 1017 slides sampled in 2005, 637 (63%) had proper smear size, 492 (48%) proper thickness and 884 (87%) proper staining; the corresponding figures were 972 (100%), 748 (77%) and 809 (99.6%) for the 972 slides rechecked in 2006. After training, the quality of size and staining of smear preparation had significantly improved (P <0.001) in 2006. Rechecking of 981 readable slides in 2005 identified 3 (0.3%) high false-negatives, 3 (16.7%) low false-positives and 26 (2.8%) low false-negatives; the corresponding errors were 3 (0.3%), 8 (28.6%) and 12 (1.3%) for the 972 slides rechecked in 2006. Of the eight laboratories, two (25%) and four (50%) reached 80% sensitivity in 2005 and 2006, respectively. CONCLUSION: Technical training and EQA improved the quality of sputum smear microscopy services.
AB - OBJECTIVE: To evaluate the quality of sputum smear microscopy in nine Taiwan Centers for Disease Control contract laboratories, an external quality assessment (EQA) programme has been implemented since 2005. DESIGN: A sampling strategy based on the lot quality assurance system was applied to select slides for rechecking. Supervisory visits and technical training were conducted to determine the causes of errors and to take corrective action. RESULTS: Of the 1017 slides sampled in 2005, 637 (63%) had proper smear size, 492 (48%) proper thickness and 884 (87%) proper staining; the corresponding figures were 972 (100%), 748 (77%) and 809 (99.6%) for the 972 slides rechecked in 2006. After training, the quality of size and staining of smear preparation had significantly improved (P <0.001) in 2006. Rechecking of 981 readable slides in 2005 identified 3 (0.3%) high false-negatives, 3 (16.7%) low false-positives and 26 (2.8%) low false-negatives; the corresponding errors were 3 (0.3%), 8 (28.6%) and 12 (1.3%) for the 972 slides rechecked in 2006. Of the eight laboratories, two (25%) and four (50%) reached 80% sensitivity in 2005 and 2006, respectively. CONCLUSION: Technical training and EQA improved the quality of sputum smear microscopy services.
KW - External quality assessment
KW - Mycobacteriology
KW - Sputum smear microscopy
KW - Taiwan
KW - Tuberculosis
UR - http://www.scopus.com/inward/record.url?scp=67649522697&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=67649522697&partnerID=8YFLogxK
M3 - Article
C2 - 19383194
AN - SCOPUS:67649522697
SN - 1027-3719
VL - 13
SP - 606
EP - 612
JO - International Journal of Tuberculosis and Lung Disease
JF - International Journal of Tuberculosis and Lung Disease
IS - 5
ER -