Evaluation of expanded bed adsorption chromatography for extraction of prothrombin complex from Cohn Supernatant I

Karl B. McCann, Peter T. Gomme, John Wu, Joseph Bertolini

研究成果: 雜誌貢獻文章同行評審

4 引文 斯高帕斯(Scopus)

摘要

This study evaluated the feasibility of substituting expanded bed adsorption (EBA) chromatography for an existing chromatographic purification process for the isolation of prothrombin complex concentrate (PCC) from Cohn Supernatant I. The EBA chromatography (Streamline) resins were compared to the current DEAE-cellulose resin for the extraction of PCC from Cohn SNI. EBA chromatography resins efficiently bound PCC from Cohn SNI at a significantly higher flow rate of up to 300 cm/h compared to 30 cm/h for the current DEAE-cellulose process. Composition and yield of the recovered PCC reflected the elution conditions used. The results indicate that EBA chromatography could be used to efficiently produce PCC comparable to existing products.
原文英語
頁(從 - 到)227-233
頁數7
期刊Biologicals
36
發行號4
DOIs
出版狀態已發佈 - 7月 1 2008
對外發佈

ASJC Scopus subject areas

  • 免疫學
  • 微生物學
  • 傳染性疾病

指紋

深入研究「Evaluation of expanded bed adsorption chromatography for extraction of prothrombin complex from Cohn Supernatant I」主題。共同形成了獨特的指紋。

引用此