TY - JOUR
T1 - Estimating the Delivery Efficiency of Drug-Loaded Microbubbles in Cancer Cells with Ultrasound and Bioluminescence Imaging
AU - Liao, Ai Ho
AU - Li, Ying Kai
AU - Lee, Wei Jiunn
AU - Wu, Ming Fang
AU - Liu, Hao Li
AU - Kuo, Min Liang
N1 - Funding Information:
The authors thank the S-Sharp Corporation in Taiwan for kindly providing the Prospect US imaging system. This work was supported in part by the National Taiwan University Center for Genomic Medicine and grant nos. NSC 99-2218-E-011-031 and NSC 100-2628-E-011-015-MY3 from the National Science Council of Taiwan .
Copyright:
Copyright 2014 Elsevier B.V., All rights reserved.
PY - 2012/11
Y1 - 2012/11
N2 - The application of drug-loaded microbubbles (MBs) in combination with ultrasound (US), which results in an increase in capillary permeability at the site of US-sonication-induced MB destruction, may be an efficient method of localized drug delivery. This study investigated the mechanism underlying the US-mediated release of luciferin-loaded MBs through the blood vessels to targeted cells using an in vivo bioluminescence imaging (BLI) system. The luciferin-loaded MBs comprised an albumin shell with a diameter of 1234 ± 394 nm (mean ± SD) and contained 2.48 × 109 bubbles/mL; within each MB, the concentration of encapsulated luciferin was 1.48 × 10-10 mg/bubble. The loading efficiency of luciferin in MBs was only about 19.8%, while maintaining both the bioluminescence and acoustic properties. In vitro and in vivo BLI experiments were performed to evaluate the US-mediated release of luciferin-loaded MBs. For in vitro results, the increase in light emission of luciferin-loaded albumin-shelled MBs after destruction via US sonication (6.24 ± 0.72 × 107 photons/s) was significantly higher than that in the luciferin-loaded albumin-shelled MBs (3.11 ± 0.33 × 107 photons/s) (p <0.05). The efficiency of the US-mediated release of luciferin-loaded MBs in 4T1-luc2 tumor-bearing mice was also estimated. The signal intensity of the tumor with US destruction at 3 W/cm2 for 30 s was significantly higher than without US destruction at 3 (p = 0.025), 5 (p = 0.013), 7 (p = 0.012) and 10 (p = 0.032) min after injecting luciferin-loaded albumin-shelled MBs. The delivery efficiency was, thus, improved with US-mediated release, allowing reduction of the total injection dose of luciferin.
AB - The application of drug-loaded microbubbles (MBs) in combination with ultrasound (US), which results in an increase in capillary permeability at the site of US-sonication-induced MB destruction, may be an efficient method of localized drug delivery. This study investigated the mechanism underlying the US-mediated release of luciferin-loaded MBs through the blood vessels to targeted cells using an in vivo bioluminescence imaging (BLI) system. The luciferin-loaded MBs comprised an albumin shell with a diameter of 1234 ± 394 nm (mean ± SD) and contained 2.48 × 109 bubbles/mL; within each MB, the concentration of encapsulated luciferin was 1.48 × 10-10 mg/bubble. The loading efficiency of luciferin in MBs was only about 19.8%, while maintaining both the bioluminescence and acoustic properties. In vitro and in vivo BLI experiments were performed to evaluate the US-mediated release of luciferin-loaded MBs. For in vitro results, the increase in light emission of luciferin-loaded albumin-shelled MBs after destruction via US sonication (6.24 ± 0.72 × 107 photons/s) was significantly higher than that in the luciferin-loaded albumin-shelled MBs (3.11 ± 0.33 × 107 photons/s) (p <0.05). The efficiency of the US-mediated release of luciferin-loaded MBs in 4T1-luc2 tumor-bearing mice was also estimated. The signal intensity of the tumor with US destruction at 3 W/cm2 for 30 s was significantly higher than without US destruction at 3 (p = 0.025), 5 (p = 0.013), 7 (p = 0.012) and 10 (p = 0.032) min after injecting luciferin-loaded albumin-shelled MBs. The delivery efficiency was, thus, improved with US-mediated release, allowing reduction of the total injection dose of luciferin.
KW - High-frequency ultrasound
KW - In vivo bioluminescence imaging system
KW - Luciferase-expressing breast cancer cell
KW - Luciferin-loaded microbubbles
UR - http://www.scopus.com/inward/record.url?scp=84866977909&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84866977909&partnerID=8YFLogxK
U2 - 10.1016/j.ultrasmedbio.2012.07.013
DO - 10.1016/j.ultrasmedbio.2012.07.013
M3 - Article
C2 - 22929655
AN - SCOPUS:84866977909
SN - 0301-5629
VL - 38
SP - 1938
EP - 1948
JO - Ultrasound in Medicine and Biology
JF - Ultrasound in Medicine and Biology
IS - 11
ER -