TY - JOUR
T1 - Effects of post-curing light intensity on the trueness, compressive strength, and resin polymerization characteristics of 3D-printed 3-unit fixed dental prostheses
AU - Sahrir, Citra Dewi
AU - Lin, Wei Shao
AU - Wang, Chin Wei
AU - Lin, Wei Chun
N1 - Publisher Copyright:
© 2024 by the American College of Prosthodontists.
PY - 2024
Y1 - 2024
N2 - Purpose: To investigate the effect of different post-curing light intensities on the trueness, compressive strength, and resin polymerization of 3D-printed 3-unit fixed dental prostheses (FPD). Materials and Methods: A total of 60 specimens were prepared to support a 3-unit FDP with a deep chamfer marginal design, utilizing computer-aided design and computer-aided manufacturing (CAD-CAM) technology. Light-polymerizing FDP resin with varying light intensities (105, 210, 420, and 840 mW/cm2) was employed for 10 min. Subsequently, trueness assessment, fracture load testing, scanning electron microscopy (SEM) surface examination, and Fourier-Transform Infrared (FTIR) analysis were conducted. A one-way analysis of variance (ANOVA) was performed to ascertain the differences between the experimental groups (p < 0.05). Results: The group exposed to 210 mW/cm2 showed the highest trueness (57.6 ± 2.1 µm), while the 840 mW/cm2 group had the highest deviation (79.3 ± 2.7 µm) (p < 0.001). Significant differences in fracture resistance were found between groups (p < 0.001), with mean fracture strengths of 1149.77 ± 67.81 N, 1264.92 ± 39.06 N, 1331.34 ± 53.62 N, and 1439.93 ± 34.58 N for light intensities of 105, 210, 420, and 840 mW/cm2, respectively (p < 0.001). The resin polymerization analysis shows a peak intensity surge at 3579 cm−1 for O-H and C-H stretching vibrations, except in samples exposed to 105 mw/cm2 light, with the lowest peak at 2890 cm−1. The performance of resin polymerization is most significant under the condition of 840 mW/cm2. Conclusion: The light intensity of 210 mW/cm2 exhibited the highest trueness, while the 840 mW/cm2 group showed the highest deviation. However, the light intensity of 840 mW/cm2 demonstrated the highest compressive strength. Furthermore, polymerization occurred at all post-treatment light intensities except 105 mW/cm2. These findings indicate that while low-intensity usage offers greater trueness, high-intensity usage provides better compressive strength and polymerization. Therefore, 210 mW/cm2 could be the recommended solution for post-curing.
AB - Purpose: To investigate the effect of different post-curing light intensities on the trueness, compressive strength, and resin polymerization of 3D-printed 3-unit fixed dental prostheses (FPD). Materials and Methods: A total of 60 specimens were prepared to support a 3-unit FDP with a deep chamfer marginal design, utilizing computer-aided design and computer-aided manufacturing (CAD-CAM) technology. Light-polymerizing FDP resin with varying light intensities (105, 210, 420, and 840 mW/cm2) was employed for 10 min. Subsequently, trueness assessment, fracture load testing, scanning electron microscopy (SEM) surface examination, and Fourier-Transform Infrared (FTIR) analysis were conducted. A one-way analysis of variance (ANOVA) was performed to ascertain the differences between the experimental groups (p < 0.05). Results: The group exposed to 210 mW/cm2 showed the highest trueness (57.6 ± 2.1 µm), while the 840 mW/cm2 group had the highest deviation (79.3 ± 2.7 µm) (p < 0.001). Significant differences in fracture resistance were found between groups (p < 0.001), with mean fracture strengths of 1149.77 ± 67.81 N, 1264.92 ± 39.06 N, 1331.34 ± 53.62 N, and 1439.93 ± 34.58 N for light intensities of 105, 210, 420, and 840 mW/cm2, respectively (p < 0.001). The resin polymerization analysis shows a peak intensity surge at 3579 cm−1 for O-H and C-H stretching vibrations, except in samples exposed to 105 mw/cm2 light, with the lowest peak at 2890 cm−1. The performance of resin polymerization is most significant under the condition of 840 mW/cm2. Conclusion: The light intensity of 210 mW/cm2 exhibited the highest trueness, while the 840 mW/cm2 group showed the highest deviation. However, the light intensity of 840 mW/cm2 demonstrated the highest compressive strength. Furthermore, polymerization occurred at all post-treatment light intensities except 105 mW/cm2. These findings indicate that while low-intensity usage offers greater trueness, high-intensity usage provides better compressive strength and polymerization. Therefore, 210 mW/cm2 could be the recommended solution for post-curing.
KW - 3D printing
KW - light intensity
KW - post-curing
KW - strength
KW - trueness
UR - http://www.scopus.com/inward/record.url?scp=85204109049&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85204109049&partnerID=8YFLogxK
U2 - 10.1111/jopr.13951
DO - 10.1111/jopr.13951
M3 - Article
AN - SCOPUS:85204109049
SN - 1059-941X
JO - Journal of Prosthodontics
JF - Journal of Prosthodontics
ER -