T1 - Dosimetric comparison of helical tomotherapy, volumetric-modulated arc therapy, intensity-modulated radiotherapy, and field-in-field technique for synchronous bilateral breast cancer
AU - Cheng, Hao Wen
AU - Chang, Chih Chieh
AU - Shiau, An Cheng
AU - Wang, Ming Hua
AU - Tsai, Jo Ting
N1 - Publisher Copyright:
© 2020 American Association of Medical Dosimetrists
PY - 2020/9/1
Y1 - 2020/9/1
N2 - Purpose: To compare the dosimetric characteristics of helical tomotherapy (HT), volumetric-modulated arc therapy (VMAT), intensity-modulated radiotherapy (IMRT), and tangential field-in-field technique (FIF) for the treatment of synchronous bilateral breast cancer (SBBC). Methods and Materials: Ten patients with early-stage unilateral breast cancer were selected for simulating the patients with SBBC in this retrospective analysis. Treatment plans with HT, VMAT, IMRT, and FIF were generated for each patient with a total dose of 50.4 Gy in 28 fractions to the target. Plan quality, namely conformity index (CI), homogeneity index (HI), dose-volume statistics of organs at risk (OARs), and beam-on time (BOT), were evaluated. Results: HT plans showed a lower mean heart dose (3.53 ± 0.31Gy) compared with the other plans (VMAT = 5.6 ± 1.36 Gy, IMRT = 3.80 ± 0.76 Gy, and FIF = 4.84 ± 2.13 Gy). Moreover, HT plans showed a significantly lower mean lung dose (p < 0.01) compared with the other plans: mean right lung doses were 6.81 ± 0.67, 10.32 ± 1.04, 9.07 ± 1.21, and 10.03 ± 1.22 Gy and mean left lung doses were 6.33 ± 0.87, 8.82 ± 0.91, 7.84 ± 1.07, and 8.64 ± 0.99 Gy for HT, VMAT, IMRT, and FIF plans, respectively. The mean dose to the left anterior descending artery was significantly lower in HT plans (p < 0.01) than in the other plans: HT = 19.41 ± 0.51 Gy, VMAT = 25.77 ± 7.23 Gy, IMRT = 27.87 ± 6.48 Gy, and FIF = 30.95 ± 10.17 Gy. FIF plans showed a worse CI and HI compared with the other plans. VMAT plans showed shorter BOT (average, 3.9 ± 0.2 minutes) than did HT (average, 11.0 ± 3.0 minutes), IMRT (average, 6.1 ± 0.5 minutes), and FIF (average, 4.6 ± 0.7 minutes) plans. Conclusions: In a dosimetric comparison for SBBC, HT provided the most favorable dose sparing of OARs. However, HT with longer BOT may increase patient discomfort and treatment uncertainty. VMAT enabled shorter BOT with acceptable doses to OARs and had a better CI than did FIF and IMRT.
AB - Purpose: To compare the dosimetric characteristics of helical tomotherapy (HT), volumetric-modulated arc therapy (VMAT), intensity-modulated radiotherapy (IMRT), and tangential field-in-field technique (FIF) for the treatment of synchronous bilateral breast cancer (SBBC). Methods and Materials: Ten patients with early-stage unilateral breast cancer were selected for simulating the patients with SBBC in this retrospective analysis. Treatment plans with HT, VMAT, IMRT, and FIF were generated for each patient with a total dose of 50.4 Gy in 28 fractions to the target. Plan quality, namely conformity index (CI), homogeneity index (HI), dose-volume statistics of organs at risk (OARs), and beam-on time (BOT), were evaluated. Results: HT plans showed a lower mean heart dose (3.53 ± 0.31Gy) compared with the other plans (VMAT = 5.6 ± 1.36 Gy, IMRT = 3.80 ± 0.76 Gy, and FIF = 4.84 ± 2.13 Gy). Moreover, HT plans showed a significantly lower mean lung dose (p < 0.01) compared with the other plans: mean right lung doses were 6.81 ± 0.67, 10.32 ± 1.04, 9.07 ± 1.21, and 10.03 ± 1.22 Gy and mean left lung doses were 6.33 ± 0.87, 8.82 ± 0.91, 7.84 ± 1.07, and 8.64 ± 0.99 Gy for HT, VMAT, IMRT, and FIF plans, respectively. The mean dose to the left anterior descending artery was significantly lower in HT plans (p < 0.01) than in the other plans: HT = 19.41 ± 0.51 Gy, VMAT = 25.77 ± 7.23 Gy, IMRT = 27.87 ± 6.48 Gy, and FIF = 30.95 ± 10.17 Gy. FIF plans showed a worse CI and HI compared with the other plans. VMAT plans showed shorter BOT (average, 3.9 ± 0.2 minutes) than did HT (average, 11.0 ± 3.0 minutes), IMRT (average, 6.1 ± 0.5 minutes), and FIF (average, 4.6 ± 0.7 minutes) plans. Conclusions: In a dosimetric comparison for SBBC, HT provided the most favorable dose sparing of OARs. However, HT with longer BOT may increase patient discomfort and treatment uncertainty. VMAT enabled shorter BOT with acceptable doses to OARs and had a better CI than did FIF and IMRT.
KW - Bilateral breast
KW - IMRT
KW - Tomotherapy
KW - VMAT
UR - http://www.scopus.com/inward/record.url?scp=85080060204&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85080060204&partnerID=8YFLogxK
U2 - 10.1016/j.meddos.2020.01.006
DO - 10.1016/j.meddos.2020.01.006
M3 - Article
C2 - 32122694
AN - SCOPUS:85080060204
SN - 0958-3947
VL - 45
SP - 271
EP - 277
JO - Medical Dosimetry
JF - Medical Dosimetry
IS - 3
ER -