N2 - We present in this communication an algorithm that offers continuous, on- line, real-time analysis of the power spectrum (CORAPS) of systemic arterial pressure (SAP) signals. Based on direct fast Fourier transform of raw SAP signals into power spectral density, it is suitable for the delineation of acute SAP spectral changes over time after physiological or pharmacological perturbations. Thus it is an improvement over most current methods, which only generate the spectra off-line or from intermittent data. Furthermore, all executions can be accomplished economically with a general-purpose personal computer. We demonstrated and quantified vivid sequential alterations in the low-frequency components (<3 Hz) of the SAP spectrum, which purportedly reflect the influence of vasomotor, baroreceptor, and respiratory activity on SAP during pentobarbital administration or transient hypertension. Three window options incorporated into the algorithm further improved the frequency or temporal resolution and discrimination of the spectral changes during abrupt hypertension or hypotension. Thus our CORAPS algorithm may be useful as an on-line monitor for acute hemodynamic changes.
AB - We present in this communication an algorithm that offers continuous, on- line, real-time analysis of the power spectrum (CORAPS) of systemic arterial pressure (SAP) signals. Based on direct fast Fourier transform of raw SAP signals into power spectral density, it is suitable for the delineation of acute SAP spectral changes over time after physiological or pharmacological perturbations. Thus it is an improvement over most current methods, which only generate the spectra off-line or from intermittent data. Furthermore, all executions can be accomplished economically with a general-purpose personal computer. We demonstrated and quantified vivid sequential alterations in the low-frequency components (<3 Hz) of the SAP spectrum, which purportedly reflect the influence of vasomotor, baroreceptor, and respiratory activity on SAP during pentobarbital administration or transient hypertension. Three window options incorporated into the algorithm further improved the frequency or temporal resolution and discrimination of the spectral changes during abrupt hypertension or hypotension. Thus our CORAPS algorithm may be useful as an on-line monitor for acute hemodynamic changes.
KW - personal computer
KW - power spectrum
KW - rat
KW - two- and three-dimensional power spectrogram
UR - http://www.scopus.com/inward/record.url?scp=0027236249&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0027236249&partnerID=8YFLogxK
U2 - 10.1152/ajpheart.1993.264.6.h2208
DO - 10.1152/ajpheart.1993.264.6.h2208
M3 - Article
C2 - 8322952
AN - SCOPUS:0027236249
SN - 0002-9513
VL - 264
SP - H2208-H2213
JO - American Journal of Physiology - Heart and Circulatory Physiology
JF - American Journal of Physiology - Heart and Circulatory Physiology
IS - 6 33-6
ER -