T1 - Agreement of cardiac output measurement between pulse contour analysis and thermodilution in various body positions
T2 - A porcine study
AU - Shih, Ping Cheng
AU - Hung, Yu Chun
AU - Chen, Ying Lun
AU - Tsai, Hsin Jung
AU - Chen, Chia Ying
AU - Huang, Chun Jen
PY - 2013/5/15
Y1 - 2013/5/15
N2 - Background: We elucidated the effects of various body positions on the agreement of cardiac output (CO) measurement between pulse contour analysis with the PiCCO monitor and thermodilution with pulmonary artery catheterization. Methods: Fifteen anesthetized and mechanically ventilated pigs (40 ± 2 kg) were sequentially placed in various positions to facilitate simultaneous CO measurement. Between-methods agreement was assessed using the Bland-Altman method. Trending ability was assessed using Pearson product-moment correlation coefficient analysis. Results: In supine, reverse Trendelenburg, Trendelenburg, and left lateral decubitus (lateral) positions, CO measured by these two methods was comparable (4.9 ± 1.5 versus 4.6 ± 1.6 L/min, 4.6 ± 2.2 versus 4.8 ± 1.8 L/min, 5.1 ± 2.1 versus 4.9 ± 2.1 L/min, and 5.4 ± 1.8 versus 5.0 ± 1.6 L/min; all P > 0.05). Mean bias between methods and limits of agreement (percentage error) were 0.3 ± 2.9 L/min (61%), -0.3 ± 3.3 L/min (71%), 0.1 ± 4.1 L/min (77%), and 0.5 ± 3.7 L/min (71%). Directional changes of paired CO revealed 66% (reverse Trendelenburg), 57% (Trendelenburg), and 66% (lateral) concordance. The correlation coefficient (r2) was 0.199, 0.127, and 0.108. For paired CO ≤6 L/min, mean bias between methods and limits of agreement (percentage error) were 0.2 ± 1.0 L/min (25%), -0.1 ± 1.0 L/min (28%), 0.2 ± 1.1 L/min (29%), and 0.5 ± 0.9 L/min (23%). Directional changes of paired CO revealed 84% (reverse Trendelenburg), 76% (Trendelenburg), and 65% (lateral) concordance. The correlation coefficient (r2) was 0.583, 0.626, and 0.213. Conclusions: The mean CO measured by pulse contour analysis and thermodilution did not agree well in various body positions. Moreover, the measurements tended to trend differently in response to positional changes. For paired CO ≤6 L/min, however, the between-methods agreement and the trending ability improved significantly.
AB - Background: We elucidated the effects of various body positions on the agreement of cardiac output (CO) measurement between pulse contour analysis with the PiCCO monitor and thermodilution with pulmonary artery catheterization. Methods: Fifteen anesthetized and mechanically ventilated pigs (40 ± 2 kg) were sequentially placed in various positions to facilitate simultaneous CO measurement. Between-methods agreement was assessed using the Bland-Altman method. Trending ability was assessed using Pearson product-moment correlation coefficient analysis. Results: In supine, reverse Trendelenburg, Trendelenburg, and left lateral decubitus (lateral) positions, CO measured by these two methods was comparable (4.9 ± 1.5 versus 4.6 ± 1.6 L/min, 4.6 ± 2.2 versus 4.8 ± 1.8 L/min, 5.1 ± 2.1 versus 4.9 ± 2.1 L/min, and 5.4 ± 1.8 versus 5.0 ± 1.6 L/min; all P > 0.05). Mean bias between methods and limits of agreement (percentage error) were 0.3 ± 2.9 L/min (61%), -0.3 ± 3.3 L/min (71%), 0.1 ± 4.1 L/min (77%), and 0.5 ± 3.7 L/min (71%). Directional changes of paired CO revealed 66% (reverse Trendelenburg), 57% (Trendelenburg), and 66% (lateral) concordance. The correlation coefficient (r2) was 0.199, 0.127, and 0.108. For paired CO ≤6 L/min, mean bias between methods and limits of agreement (percentage error) were 0.2 ± 1.0 L/min (25%), -0.1 ± 1.0 L/min (28%), 0.2 ± 1.1 L/min (29%), and 0.5 ± 0.9 L/min (23%). Directional changes of paired CO revealed 84% (reverse Trendelenburg), 76% (Trendelenburg), and 65% (lateral) concordance. The correlation coefficient (r2) was 0.583, 0.626, and 0.213. Conclusions: The mean CO measured by pulse contour analysis and thermodilution did not agree well in various body positions. Moreover, the measurements tended to trend differently in response to positional changes. For paired CO ≤6 L/min, however, the between-methods agreement and the trending ability improved significantly.
KW - Bland-Altman
KW - Lateral decubitus
KW - Pulse contour analysis
KW - Reverse Trendelenburg
KW - Supine
KW - Thermodilution
KW - Trendelenburg
UR - http://www.scopus.com/inward/record.url?scp=84876410369&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84876410369&partnerID=8YFLogxK
U2 - 10.1016/j.jss.2012.07.012
DO - 10.1016/j.jss.2012.07.012
M3 - Article
C2 - 22884452
AN - SCOPUS:84876410369
SN - 0022-4804
VL - 181
SP - 315
EP - 322
JO - Journal of Surgical Research
JF - Journal of Surgical Research
IS - 2
ER -