TY - JOUR
T1 - Time-Shift Correlation Algorithm for P300 Event Related Potential Brain-Computer Interface Implementation
AU - Liu, Ju Chi
AU - Chou, Hung Chyun
AU - Chen, Chien Hsiu
AU - Lin, Yi Tseng
AU - Kuo, Chung Hsien
N1 - Publisher Copyright:
© 2016 Ju-Chi Liu et al.
PY - 2016
Y1 - 2016
N2 - A high efficient time-shift correlation algorithm was proposed to deal with the peak time uncertainty of P300 evoked potential for a P300-based brain-computer interface (BCI). The time-shift correlation series data were collected as the input nodes of an artificial neural network (ANN), and the classification of four LED visual stimuli was selected as the output node. Two operating modes, including fast-recognition mode (FM) and accuracy-recognition mode (AM), were realized. The proposed BCI system was implemented on an embedded system for commanding an adult-size humanoid robot to evaluate the performance from investigating the ground truth trajectories of the humanoid robot. When the humanoid robot walked in a spacious area, the FM was used to control the robot with a higher information transfer rate (ITR). When the robot walked in a crowded area, the AM was used for high accuracy of recognition to reduce the risk of collision. The experimental results showed that, in 100 trials, the accuracy rate of FM was 87.8% and the average ITR was 52.73 bits/min. In addition, the accuracy rate was improved to 92% for the AM, and the average ITR decreased to 31.27 bits/min. due to strict recognition constraints.
AB - A high efficient time-shift correlation algorithm was proposed to deal with the peak time uncertainty of P300 evoked potential for a P300-based brain-computer interface (BCI). The time-shift correlation series data were collected as the input nodes of an artificial neural network (ANN), and the classification of four LED visual stimuli was selected as the output node. Two operating modes, including fast-recognition mode (FM) and accuracy-recognition mode (AM), were realized. The proposed BCI system was implemented on an embedded system for commanding an adult-size humanoid robot to evaluate the performance from investigating the ground truth trajectories of the humanoid robot. When the humanoid robot walked in a spacious area, the FM was used to control the robot with a higher information transfer rate (ITR). When the robot walked in a crowded area, the AM was used for high accuracy of recognition to reduce the risk of collision. The experimental results showed that, in 100 trials, the accuracy rate of FM was 87.8% and the average ITR was 52.73 bits/min. In addition, the accuracy rate was improved to 92% for the AM, and the average ITR decreased to 31.27 bits/min. due to strict recognition constraints.
UR - http://www.scopus.com/inward/record.url?scp=84983761106&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84983761106&partnerID=8YFLogxK
U2 - 10.1155/2016/3039454
DO - 10.1155/2016/3039454
M3 - Article
C2 - 27579033
AN - SCOPUS:84983761106
SN - 1687-5265
VL - 2016
JO - Computational Intelligence and Neuroscience
JF - Computational Intelligence and Neuroscience
M1 - 3039454
ER -