TY - JOUR
T1 - The cushion scanning technique
T2 - a method of dynamic tongue sonography and its comparison with the transducer-skin coupling scanning technique during swallowing.
AU - Peng, Chien Lun
AU - Jost-Brinkmann, Paul Georg
AU - Miethke, Rainer Reginald Henno
PY - 1996/3
Y1 - 1996/3
N2 - RATIONALE AND OBJECTIVES: We describe the cushion scanning technique (CST), which solves common difficulties encountered during ultrasound investigations of swallowing. These problems arise when the transducer is held in direct contact with the submental area. Some of these problems include movements of the ultrasound transducer during swallowing and compression of the submental region, which causes abnormal swallowing patterns. METHODS: To compare ultrasound images produced with the conventional hand-held transducer-skin coupling scanning technique with the CST, we studied five participants with no clinical signs of tongue dysfunction. All tongue movements were recorded by real-time B+M-mode sonography. RESULTS: Images produced with the hand-held transducer were found to be unstable because the transducer moved during swallowing, thereby changing the scanning section. By contrast, the transducer and the participant's head remained in a constant position throughout the CST trial. There was no obvious compression of the submental muscles. CONCLUSION: The CST allows for a better intraindividual reproducibility of the swallowing pattern and for a more standardized and objective ultrasound examination than the hand-held transducer-skin coupling scanning technique.
AB - RATIONALE AND OBJECTIVES: We describe the cushion scanning technique (CST), which solves common difficulties encountered during ultrasound investigations of swallowing. These problems arise when the transducer is held in direct contact with the submental area. Some of these problems include movements of the ultrasound transducer during swallowing and compression of the submental region, which causes abnormal swallowing patterns. METHODS: To compare ultrasound images produced with the conventional hand-held transducer-skin coupling scanning technique with the CST, we studied five participants with no clinical signs of tongue dysfunction. All tongue movements were recorded by real-time B+M-mode sonography. RESULTS: Images produced with the hand-held transducer were found to be unstable because the transducer moved during swallowing, thereby changing the scanning section. By contrast, the transducer and the participant's head remained in a constant position throughout the CST trial. There was no obvious compression of the submental muscles. CONCLUSION: The CST allows for a better intraindividual reproducibility of the swallowing pattern and for a more standardized and objective ultrasound examination than the hand-held transducer-skin coupling scanning technique.
UR - http://www.scopus.com/inward/record.url?scp=0030099051&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0030099051&partnerID=8YFLogxK
U2 - 10.1016/S1076-6332(96)80449-1
DO - 10.1016/S1076-6332(96)80449-1
M3 - Article
C2 - 8796671
AN - SCOPUS:0030099051
SN - 1076-6332
VL - 3
SP - 239
EP - 244
JO - Academic Radiology
JF - Academic Radiology
IS - 3
ER -