TY - JOUR
T1 - Should we use the shorter Thai-version quality of life and symptoms questionnaires in women with overactive bladder?
AU - Bunyavejchevin, Suvit
AU - Liao, Limin
AU - Lu, Shing Hwa
AU - Choo, Myung Soo
AU - Rabbani, Khalid Javed
AU - Havanond, Piyalamporn
N1 - Publisher Copyright:
© 2015 The Authors Journal of Obstetrics and Gynaecology Research © 2015 Japan Society of Obstetrics and Gynecology.
PY - 2015/8/1
Y1 - 2015/8/1
N2 - Aim The aim of this study was to test: (i) the validation and reliability of the Thai versions of overactive bladder (OAB) questionnaires (the 8-item and 3-item Overactive Bladder Symptoms Score questionnaires [OAB-v8 and OAB-v3, respectively] and the Overactive Bladder Questionnaire [OAB-q]); and (ii) the correlation of the OAB-v8, OAB-v3, and the single-question Quality of Life Questionnaire (1-QoL) to the OAB-q in Thai women with OAB. Material and Methods During January to March 2011, 36 Thai women with OAB attending a urogynecology clinic at Chulalongkorn Hospital, Bangkok, Thailand were recruited. All questionnaires were given as a psychometric test twice, 2weeks apart. Results Cronbach's alpha of the OAB-v8 was higher (and above 0.7) than OAB-v3 at both week 0 and week 2. The intraclass correlations (ricc) were 0.64, 0.85, and 0.97 for the OABV8, OAB-v3, and OAB-q, respectively. The correlation coefficient (r) of OAB-v3 and OAB-q at weeks 0 and 2 (0.40 and 0.49) were lower than those for OAB-v8 and OAB-q at weeks 0 and 2 (0.62 and 0.62). All questions on the OAB-v3 had a lower weighted kappa than OAB-v8. There was no statistically significant difference in the OAB-q score in each level of 1-QoL score at week 0 (P = 0.12) and at week 2 (P = 0.29). Conclusion The reliability of the OAB-v3 is poorer than that of the OAB-v8. The OAB-v3 is poorer correlated to the OAB-q than to the OAB-v8. A short questionnaire, such as the OAB-v3 and the 1-QoL, has poor reliability and is poorly correlated to the OAB-q and is not recommended as a replacement for the standard questionnaires, such as the OAB-q and the OAB-v8. The OAB-v3 should only be used in large screening populations where there are time limits.
AB - Aim The aim of this study was to test: (i) the validation and reliability of the Thai versions of overactive bladder (OAB) questionnaires (the 8-item and 3-item Overactive Bladder Symptoms Score questionnaires [OAB-v8 and OAB-v3, respectively] and the Overactive Bladder Questionnaire [OAB-q]); and (ii) the correlation of the OAB-v8, OAB-v3, and the single-question Quality of Life Questionnaire (1-QoL) to the OAB-q in Thai women with OAB. Material and Methods During January to March 2011, 36 Thai women with OAB attending a urogynecology clinic at Chulalongkorn Hospital, Bangkok, Thailand were recruited. All questionnaires were given as a psychometric test twice, 2weeks apart. Results Cronbach's alpha of the OAB-v8 was higher (and above 0.7) than OAB-v3 at both week 0 and week 2. The intraclass correlations (ricc) were 0.64, 0.85, and 0.97 for the OABV8, OAB-v3, and OAB-q, respectively. The correlation coefficient (r) of OAB-v3 and OAB-q at weeks 0 and 2 (0.40 and 0.49) were lower than those for OAB-v8 and OAB-q at weeks 0 and 2 (0.62 and 0.62). All questions on the OAB-v3 had a lower weighted kappa than OAB-v8. There was no statistically significant difference in the OAB-q score in each level of 1-QoL score at week 0 (P = 0.12) and at week 2 (P = 0.29). Conclusion The reliability of the OAB-v3 is poorer than that of the OAB-v8. The OAB-v3 is poorer correlated to the OAB-q than to the OAB-v8. A short questionnaire, such as the OAB-v3 and the 1-QoL, has poor reliability and is poorly correlated to the OAB-q and is not recommended as a replacement for the standard questionnaires, such as the OAB-q and the OAB-v8. The OAB-v3 should only be used in large screening populations where there are time limits.
KW - 3-item Overactive Bladder Symptoms Score Questionnaire
KW - 8-item Overactive Bladder Symptoms Score Questionnaire
KW - overactive bladder
KW - Overactive Bladder Questionnaire
KW - questionnaires
UR - http://www.scopus.com/inward/record.url?scp=84938206449&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84938206449&partnerID=8YFLogxK
U2 - 10.1111/jog.12699
DO - 10.1111/jog.12699
M3 - Article
C2 - 26081949
AN - SCOPUS:84938206449
SN - 1341-8076
VL - 41
SP - 1260
EP - 1265
JO - Journal of Obstetrics and Gynaecology Research
JF - Journal of Obstetrics and Gynaecology Research
IS - 8
ER -