Screening for high-grade carotid stenosis using a portable ultrasonography instrument

Ulf Schminke, Lillian Motsch, Li Ming Lien, Teng Yeow Tan, M. Gene Bond, James F. Toole, Charles H. Tegeler

Research output: Contribution to journalArticlepeer-review

2 Citations (Scopus)

Abstract

Background and Purpose. We investigated the diagnostic performance of a brief Power Doppler Imaging (PDI) screening examination for carotid artery stenoses using a newly developed portable instrument. Methods. A highly experienced sonographer screened in total 152 carotid arteries by either continuous wave (cw) Doppler (n = 50) or a lightweight (2.4 kg) portable duplex device (n = 102) in a prospective study of 76 high-risk patients. The screening protocols included either spectrum analysis and frequency shift measurement in both internal carotid arteries with cw-Doppler or determination of area and diameter ratios in transverse and longitudinal views of both carotid arteries in B-mode and with PDI, but without velocity measurement. Both protocols were evaluated against a complete routine duplex ultrasonography examination. Results. According to the complete examination, stenoses were <50% in 73 of 102 (71.6%), 50-75% in 19 of 102 (18.6%), 75-95% in 7 of 102 (6.9%), and occluded in 3 of 102 (2.9%) arteries (PDI cohort), and <50% in 39 of 50 (78%), 50-75% in 8 of 50 (16%), 75-95% in 2 of 50 (4%), and occluded in 1 of 50 (2%) artery (cw-Doppler cohort). Mean screening time was 8.8 ± 2.5 minute (PDI) and 9.4 ± 2.6 minute (cw-Doppler). For stenoses >75%, A z values (area under the receiver operating characteristics curve) were 0.897 for area ratios, 0.843 for diameter ratios (PDI protocol) and 1.0 for the cw-Doppler protocol. Conclusions. The diagnostic performance of the cw-Doppler protocol was superior to the PDI protocol. Nevertheless, both protocols appear suitable as inexpensive screening strategies to identify subjects with >75% stenosis measured by carotid Doppler ultrasound. However, these preliminary data need further verification.

Original languageEnglish
Pages (from-to)252-259
Number of pages8
JournalJournal of Neuroimaging
Volume16
Issue number3
DOIs
Publication statusPublished - Jul 2006
Externally publishedYes

Keywords

  • Carotid artery stenosis
  • Power Doppler imaging
  • Screening
  • Ultrasonography

ASJC Scopus subject areas

  • Clinical Neurology
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Screening for high-grade carotid stenosis using a portable ultrasonography instrument'. Together they form a unique fingerprint.

Cite this