TY - JOUR
T1 - Refractive-error quality of life (RQL) in patients with AcrySof IQ aspherical intraocular lenses
AU - Lin, I. Chan
AU - Wang, I. Jong
AU - Lei, Mei Shu
AU - Hu, Fung Rong
AU - Lin, Luke L.k.
PY - 2010
Y1 - 2010
N2 - Purpose: To compare refractive-error quality of life, and spherical aberration in pseudophakic eyes with an aspherical intraocular lens (AcrySof IQ) vs. a conventional spherical intraocular lens (AcrySof Single-Piece). Methods: 65 patients were randomized to implantation of either an aspherical IOL (Alcon AcrySof IQ) (30 eyes) or a spherical IOL (Alcon AcrySof Single-Piece (35 eyes). Three months postoperati- vely, complete ophthalmologic examinations including uncorrec- ted visual acuity (UCVA), best spectacle-corrected visual acuity (BCVA), and a wavefront analysis were performed. Patients com- pleted the National Eye Institute Refractive Error Quality of life Instrument (NEI RQL) to evaluate vision-related quality of life. results: The mean postoperative best-corrected visual acuity was 0.09±0.07 logMAR in the aspherical group and 0.12±0.08 in the spherical group, and the difference was not statistically significant. Spherical aberrations were significantly lower in the aspherical group (0.12±0.23 μm), than in the spherical group (0.33±0.20 μm) (P=0.001). Patients with aspherical AcrySof IQ IOLs implantation also experienced less difficulties driving at night (P=0.04), but the difference was not significant after Bonferroni correction. Conclusion: The NEI RQL instrument is sensitive enough to detect the visual benefit of cataract surgery. The aspherical AcrySof IQ IOL reduces both spherical aberration and total higher-order aberrations, compared with the performance achieved by the sphe- rical AcrySof Single-Piece IOL. Although the difference between the two IOLs is not statistically significant, there is a tendency toward the association of objective optical performance of asphe- rical AcrySof IQ IOLs with a subjective improvement in patients' night driving.
AB - Purpose: To compare refractive-error quality of life, and spherical aberration in pseudophakic eyes with an aspherical intraocular lens (AcrySof IQ) vs. a conventional spherical intraocular lens (AcrySof Single-Piece). Methods: 65 patients were randomized to implantation of either an aspherical IOL (Alcon AcrySof IQ) (30 eyes) or a spherical IOL (Alcon AcrySof Single-Piece (35 eyes). Three months postoperati- vely, complete ophthalmologic examinations including uncorrec- ted visual acuity (UCVA), best spectacle-corrected visual acuity (BCVA), and a wavefront analysis were performed. Patients com- pleted the National Eye Institute Refractive Error Quality of life Instrument (NEI RQL) to evaluate vision-related quality of life. results: The mean postoperative best-corrected visual acuity was 0.09±0.07 logMAR in the aspherical group and 0.12±0.08 in the spherical group, and the difference was not statistically significant. Spherical aberrations were significantly lower in the aspherical group (0.12±0.23 μm), than in the spherical group (0.33±0.20 μm) (P=0.001). Patients with aspherical AcrySof IQ IOLs implantation also experienced less difficulties driving at night (P=0.04), but the difference was not significant after Bonferroni correction. Conclusion: The NEI RQL instrument is sensitive enough to detect the visual benefit of cataract surgery. The aspherical AcrySof IQ IOL reduces both spherical aberration and total higher-order aberrations, compared with the performance achieved by the sphe- rical AcrySof Single-Piece IOL. Although the difference between the two IOLs is not statistically significant, there is a tendency toward the association of objective optical performance of asphe- rical AcrySof IQ IOLs with a subjective improvement in patients' night driving.
KW - Aspherical intraocular lenses
KW - Night driving
KW - Refractive error quality of life
KW - Spherical aberration
UR - http://www.scopus.com/inward/record.url?scp=77952641832&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=77952641832&partnerID=8YFLogxK
U2 - 10.3921/joptom.2010.44
DO - 10.3921/joptom.2010.44
M3 - Article
AN - SCOPUS:77952641832
SN - 1888-4296
VL - 3
SP - 44
EP - 50
JO - Journal of Optometry
JF - Journal of Optometry
IS - 1
ER -