T1 - Radiofrequency catheter modification of sinus node for inappropriate sinus tachycardia
T2 - a case report.
AU - Lee, S. H.
AU - Cheng, J. J.
AU - Kuan, P.
AU - Hung, C. R.
PY - 1997/8
Y1 - 1997/8
N2 - We present here, the case of a 22-year-old male suffering from persistent tachycardia for the past 3 years. His resting pulse rate was rarely below 100 beats/min, and it frequently increased to as high as 150 beats/min even after a minimal of activity. Associated symptoms included palpitation, chest tightness, dyspnea and presyncope, either during rest or with exercise. Propranolol and verapamil could not control the tachycardia. The application of radiofrequency energy to an area in the superior right atrium that demonstrated a discrete electrogram with earliest endocardial activation during tachycardia resulted in a decrease in sinus rate from 120 beats/min to 70 beats/min. Follow-up on Holter monitor, performed one month later, demonstrated an average heart rate of 84 beats/min (range 60-125). In exercise tolerance test, the patient exercised for 9 minutes, achieving a maximum heart rate of 140 beats/min. This patient remained asymptomatic without any antiarrhythmic drug during the 3-month follow-up period. Medical management in case of patients showing disabling inappropriate sinus tachycardia refractory, sinus node modification could be considered as an suitable alternative to complete atrioventricular junctional ablation.
AB - We present here, the case of a 22-year-old male suffering from persistent tachycardia for the past 3 years. His resting pulse rate was rarely below 100 beats/min, and it frequently increased to as high as 150 beats/min even after a minimal of activity. Associated symptoms included palpitation, chest tightness, dyspnea and presyncope, either during rest or with exercise. Propranolol and verapamil could not control the tachycardia. The application of radiofrequency energy to an area in the superior right atrium that demonstrated a discrete electrogram with earliest endocardial activation during tachycardia resulted in a decrease in sinus rate from 120 beats/min to 70 beats/min. Follow-up on Holter monitor, performed one month later, demonstrated an average heart rate of 84 beats/min (range 60-125). In exercise tolerance test, the patient exercised for 9 minutes, achieving a maximum heart rate of 140 beats/min. This patient remained asymptomatic without any antiarrhythmic drug during the 3-month follow-up period. Medical management in case of patients showing disabling inappropriate sinus tachycardia refractory, sinus node modification could be considered as an suitable alternative to complete atrioventricular junctional ablation.
UR - http://www.scopus.com/inward/record.url?scp=0031202307&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0031202307&partnerID=8YFLogxK
M3 - Article
C2 - 9360339
AN - SCOPUS:0031202307
SN - 0578-1337
VL - 60
SP - 117
EP - 123
JO - Zhonghua yi xue za zhi = Chinese medical journal; Free China ed
JF - Zhonghua yi xue za zhi = Chinese medical journal; Free China ed