TY - JOUR
T1 - Quantification of endogenous metabolites by the postcolumn infused-internal standard method combined with matrix normalization factor in liquid chromatography-electrospray ionization tandem mass spectrometry
AU - Liao, Hsiao Wei
AU - Chen, Guan Yuan
AU - Wu, Ming Shiang
AU - Liao, Wei Chih
AU - Tsai, I. Lin
AU - Kuo, Ching Hua
N1 - Publisher Copyright:
© 2014 Elsevier B.V.
PY - 2015/1/2
Y1 - 2015/1/2
N2 - Quantification of endogenous metabolites has enabled the discovery of biomarkers for diagnosis and provided for an understanding of disease etiology. The standard addition and stable isotope labeled-internal standard (SIL-IS) methods are currently the most widely used approaches to quantifying endogenous metabolites, but both have some limitations for clinical measurement. In this study, we developed a new approach for endogenous metabolite quantification by the postcolumn infused-internal standard (PCI-IS) method combined with the matrix normalization factor (MNF) method. MNF was used to correct the difference in MEs between standard solution and biofluids, and PCI-IS additionally tailored the correction of the MEs for individual samples. Androstenedione and testosterone were selected as test articles to verify this new approach to quantifying metabolites in plasma. The repeatability (n= 4 runs) and intermediate precision (n= 3 days) in terms of the peak area of androstenedione and testosterone at all tested concentrations were all less than 11% relative standard deviation (RSD). The accuracy test revealed that the recoveries were between 95.72% and 113.46%. The concentrations of androstenedione and testosterone in fifty plasma samples obtained from healthy volunteers were quantified by the PCI-IS combined with the MNF method, and the quantification results were compared with the results of the SIL-IS method. The Pearson correlation test showed that the correlation coefficient was 0.98 for both androstenedione and testosterone. We demonstrated that the PCI-IS combined with the MNF method is an effective and accurate method for quantifying endogenous metabolites.
AB - Quantification of endogenous metabolites has enabled the discovery of biomarkers for diagnosis and provided for an understanding of disease etiology. The standard addition and stable isotope labeled-internal standard (SIL-IS) methods are currently the most widely used approaches to quantifying endogenous metabolites, but both have some limitations for clinical measurement. In this study, we developed a new approach for endogenous metabolite quantification by the postcolumn infused-internal standard (PCI-IS) method combined with the matrix normalization factor (MNF) method. MNF was used to correct the difference in MEs between standard solution and biofluids, and PCI-IS additionally tailored the correction of the MEs for individual samples. Androstenedione and testosterone were selected as test articles to verify this new approach to quantifying metabolites in plasma. The repeatability (n= 4 runs) and intermediate precision (n= 3 days) in terms of the peak area of androstenedione and testosterone at all tested concentrations were all less than 11% relative standard deviation (RSD). The accuracy test revealed that the recoveries were between 95.72% and 113.46%. The concentrations of androstenedione and testosterone in fifty plasma samples obtained from healthy volunteers were quantified by the PCI-IS combined with the MNF method, and the quantification results were compared with the results of the SIL-IS method. The Pearson correlation test showed that the correlation coefficient was 0.98 for both androstenedione and testosterone. We demonstrated that the PCI-IS combined with the MNF method is an effective and accurate method for quantifying endogenous metabolites.
KW - Endogenous metabolites
KW - Liquid chromatography-electrospray ionization tandem mass spectrometry
KW - Matrix effects
KW - Matrix normalization factor (MNF)
KW - Postcolumn infused-internal standard (PCI-IS)
UR - http://www.scopus.com/inward/record.url?scp=84919696578&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84919696578&partnerID=8YFLogxK
U2 - 10.1016/j.chroma.2014.11.073
DO - 10.1016/j.chroma.2014.11.073
M3 - Article
C2 - 25516166
AN - SCOPUS:84919696578
SN - 0021-9673
VL - 1375
SP - 62
EP - 68
JO - Journal of Chromatography A
JF - Journal of Chromatography A
ER -