TY - JOUR
T1 - Purification of human plasma haptoglobin by hemoglobin-affinity column chromatography
AU - Liau, Chun Yi
AU - Chang, Tsai Mu
AU - Pan, Ju Pin
AU - Chen, Wen Liang
AU - Mao, Simon J.T.
N1 - Funding Information:
This work was supported by grants NHRI-EX92-9229SI (S.J.T.M.) from the National Health Research Institute, and NSC 89-2313-B-009-001-A20 (S.J.T.M.) and NSC 90-2314-B-075-099 (J.P.P.) from the National Science Council, Taiwan. The authors thank Ms. Yu-Chi Pong for her dedicated administrative assistance.
PY - 2003/6/25
Y1 - 2003/6/25
N2 - Haptoglobin (Hp) is an acute-phase protein; its plasma levels increase consistently in response to infection and inflammation. The concentration of human plasma Hp is ranged between 1 and 1.5 mg/ml. Similar to blood type, individual human Hp is classified as Hp 1-1, 2-1, or 2-2. The structural and functional analysis of the Hp, however, has not been studied in detail due to its difficult isolation procedure. Previously, we reported a single step for the purification of porcine Hp. In this study, we established a purification method using a high capacity hemoglobin-affinity column. Briefly, DEAE-purified human hemoglobin was first coupled to Sepharose 4B to prepare an affinity column in a 15-ml bed volume. Following a flow through of human plasma and an extensive wash, the bound material was eluted with a solution of 0.15 M NaCl, pH 11 (adjusted by ammonium), to remove low-affinity bound proteins. The high-affinity bound Hp was then eluted with 0.15 M NaCl containing 5 M urea, pH 11, and collected in tubes containing 100 μl of 1 M Tris buffer, pH 7.0. The biological activity of dialyzed Hp was retained as it formed a complex with hemoglobin on a sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE). Using this procedure, approximately 10 mg of Hp 1-1, with homogeneity greater than 96%, was obtained from 15 ml of human plasma. Affinity purified Hp 2-1 or 2-2, however, contained trace amounts of apoA-I with the similar approach. The Hp could be further purified by HPLC using a Superose 12 gel-permeation chromatography, if desired, to achieve 100% purity. All the phenotypes of purified Hp consisted of α and β chains on SDS-PAGE in the presence of a reducing reagent, further confirmed by a Western blot analysis. We conclude that human hemoglobin-affinity column was most suitable for the isolation of Hp 1-1 in large quantities. Whereas, one additional step using a gel-permeation was necessary for that of Hp 2-1 and 2-2.
AB - Haptoglobin (Hp) is an acute-phase protein; its plasma levels increase consistently in response to infection and inflammation. The concentration of human plasma Hp is ranged between 1 and 1.5 mg/ml. Similar to blood type, individual human Hp is classified as Hp 1-1, 2-1, or 2-2. The structural and functional analysis of the Hp, however, has not been studied in detail due to its difficult isolation procedure. Previously, we reported a single step for the purification of porcine Hp. In this study, we established a purification method using a high capacity hemoglobin-affinity column. Briefly, DEAE-purified human hemoglobin was first coupled to Sepharose 4B to prepare an affinity column in a 15-ml bed volume. Following a flow through of human plasma and an extensive wash, the bound material was eluted with a solution of 0.15 M NaCl, pH 11 (adjusted by ammonium), to remove low-affinity bound proteins. The high-affinity bound Hp was then eluted with 0.15 M NaCl containing 5 M urea, pH 11, and collected in tubes containing 100 μl of 1 M Tris buffer, pH 7.0. The biological activity of dialyzed Hp was retained as it formed a complex with hemoglobin on a sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE). Using this procedure, approximately 10 mg of Hp 1-1, with homogeneity greater than 96%, was obtained from 15 ml of human plasma. Affinity purified Hp 2-1 or 2-2, however, contained trace amounts of apoA-I with the similar approach. The Hp could be further purified by HPLC using a Superose 12 gel-permeation chromatography, if desired, to achieve 100% purity. All the phenotypes of purified Hp consisted of α and β chains on SDS-PAGE in the presence of a reducing reagent, further confirmed by a Western blot analysis. We conclude that human hemoglobin-affinity column was most suitable for the isolation of Hp 1-1 in large quantities. Whereas, one additional step using a gel-permeation was necessary for that of Hp 2-1 and 2-2.
KW - Affinity adsorbents
KW - Glycoproteins
KW - Haptoglobin
KW - Proteins
UR - http://www.scopus.com/inward/record.url?scp=0038739410&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0038739410&partnerID=8YFLogxK
U2 - 10.1016/S1570-0232(03)00128-4
DO - 10.1016/S1570-0232(03)00128-4
M3 - Article
C2 - 12767333
AN - SCOPUS:0038739410
SN - 1570-0232
VL - 790
SP - 209
EP - 216
JO - Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences
JF - Journal of Chromatography B: Analytical Technologies in the Biomedical and Life Sciences
IS - 1-2
ER -