TY - JOUR
T1 - Meta-analysis. Comparison of F-18 Fluorodeoxyglucose-Positron Emission Tomography and Bone Scintigraphy in the Detection of Bone Metastasis in Patients with Lung Cancer
AU - Chang, Ming Che
AU - Chen, Jin Hua
AU - Liang, Ji An
AU - Lin, Cheng Chieh
AU - Yang, Kuang Tao
AU - Cheng, Kai Yuan
AU - Yeh, Jun Jun
AU - Kao, Chia Hung
PY - 2012/3
Y1 - 2012/3
N2 - Rationale and Objectives: The aim of this review was to evaluate the diagnostic properties of 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET) or PET/computed tomography (CT) and bone scintigraphy in the detection of osseous metastases in patients with lung cancer. Materials and Methods: MEDLINE was searched for relevant original articles published between January 1995 and August 2010. Inclusion criteria were as follows: FDG-PET or PET/CT and bone scintigraphy was carried out to detect bone metastases in patients with lung cancer, sufficient data were presented to construct a 2 × 2 contingency table, and histopathologic analysis and/or close clinical and imaging follow-up and/or radiographic confirmation by multiple imaging modalities was used as the reference standard. Two reviewers independently extracted data related to research design, sample size, imaging techniques, technical characteristics, reference standards, methods of imaging interpretation, and totals of true-positives, false-positives, true-negatives, and false-negatives. Stata was used to obtain per patient and per lesion pooled estimates of sensitivity, specificity, and positive and negative likelihood ratios, and areas under summary receiver-operating characteristic curves (AUCs) were calculated. Results: The pooled patient-based sensitivity of FDG-PET or PET/CT was 0.93 (95% confidence interval [CI], 0.88-0.96), specificity was 0.95 (95% CI, 0.91-0.98), and the AUC was 0.94. The pooled sensitivity of bone scans was 0.87 (95% CI, 0.79-0.93), specificity was0.82(95% CI, 0.62-0.92), and the AUC was 0.91. The pooled lesion-based sensitivity of FDG-PET or PET/CT was 0.93 (95% CI, 0.84-0.97), specificity was 0.91 (95% CI, 0.80-0.96), and the AUC was 0.97. The pooled sensitivity of bone scans was 0.92 (95% CI, 0.87-0.95), specificity was 0.57 (95% CI, 0.09-0.95), and the AUC was 0.92. Conclusions: Although FDG-PET or PET/CT has higher sensitivity and specificity than bone scintigraphy, further research with a less biased design is needed to determine the most efficacious imaging modality for the detection of metastatic lung cancer.
AB - Rationale and Objectives: The aim of this review was to evaluate the diagnostic properties of 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET) or PET/computed tomography (CT) and bone scintigraphy in the detection of osseous metastases in patients with lung cancer. Materials and Methods: MEDLINE was searched for relevant original articles published between January 1995 and August 2010. Inclusion criteria were as follows: FDG-PET or PET/CT and bone scintigraphy was carried out to detect bone metastases in patients with lung cancer, sufficient data were presented to construct a 2 × 2 contingency table, and histopathologic analysis and/or close clinical and imaging follow-up and/or radiographic confirmation by multiple imaging modalities was used as the reference standard. Two reviewers independently extracted data related to research design, sample size, imaging techniques, technical characteristics, reference standards, methods of imaging interpretation, and totals of true-positives, false-positives, true-negatives, and false-negatives. Stata was used to obtain per patient and per lesion pooled estimates of sensitivity, specificity, and positive and negative likelihood ratios, and areas under summary receiver-operating characteristic curves (AUCs) were calculated. Results: The pooled patient-based sensitivity of FDG-PET or PET/CT was 0.93 (95% confidence interval [CI], 0.88-0.96), specificity was 0.95 (95% CI, 0.91-0.98), and the AUC was 0.94. The pooled sensitivity of bone scans was 0.87 (95% CI, 0.79-0.93), specificity was0.82(95% CI, 0.62-0.92), and the AUC was 0.91. The pooled lesion-based sensitivity of FDG-PET or PET/CT was 0.93 (95% CI, 0.84-0.97), specificity was 0.91 (95% CI, 0.80-0.96), and the AUC was 0.97. The pooled sensitivity of bone scans was 0.92 (95% CI, 0.87-0.95), specificity was 0.57 (95% CI, 0.09-0.95), and the AUC was 0.92. Conclusions: Although FDG-PET or PET/CT has higher sensitivity and specificity than bone scintigraphy, further research with a less biased design is needed to determine the most efficacious imaging modality for the detection of metastatic lung cancer.
KW - Bone metastasis
KW - Bone scan
KW - Bone scintigraphy
KW - FDG-PET
KW - Lung cancer
UR - http://www.scopus.com/inward/record.url?scp=84856596362&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84856596362&partnerID=8YFLogxK
U2 - 10.1016/j.acra.2011.10.018
DO - 10.1016/j.acra.2011.10.018
M3 - Review article
C2 - 22173321
AN - SCOPUS:84856596362
SN - 1076-6332
VL - 19
SP - 349
EP - 357
JO - Academic Radiology
JF - Academic Radiology
IS - 3
ER -