TY - JOUR
T1 - MDCT angiography for evaluation of the complete vascular tree of hemodialysis fistulas
AU - Ko, Sheung Fat
AU - Huang, Chung Cheng
AU - Ng, Shu Hang
AU - Lee, Tze Yu
AU - Hsieh, Ming Jang
AU - Lee, Fan Yen
AU - Chen, Min Chi
AU - Sheen-Chen, Shyr Ming
AU - Lee, Chi Hsiung
PY - 2005/12/1
Y1 - 2005/12/1
N2 - OBJECTIVE. The purpose of our study was to assess the clinical feasibility of MDCT angiography for evaluating hemodialysis arteriovenous fistulas (AVFs). MATERIALS AND METHODS. MDCT angiography of the complete vascular trees of 36 failing AVFs or AVF-related complications (20 native and 16 polytetrafluoroethylene graft AVFs) was reviewed. The numbers and degrees of stenoses at the anastomoses, graft loops, and draining and central veins and the presence of aneurysms or thrombosis were recorded. Wilcoxon's signed rank test was used to compare the findings of MDCT angiography with those of digital subtraction angiography (DSA) (n = 10), surgery (n = 22), or both (n = 4) performed within 2-6 days. Kappa statistics were used to correlate the clinical feasibility of MDCT angiography assessed by two reviewers. RESULTS. Among the 14 AVFs examined with both MDCT angiography and DSA, no significant difference was seen in the detection and grading (p = 0.317 to > 0.999) of stenoses at various segments of the entire vascular tree. Among the 36 AVFs examined, MDCT angiography also showed no significant difference from DSA or surgery in revealing vascular stenoses, aneurysms, and thromboses from the supplying artery to central veins (p = 0.317 to > 0.999). Overall, the sensitivity, specificity, positive and negative predictive values, and accuracy of MDCT angiography in lesion detection were 98.7%, 97.5%, 98.8%, 97.2%, and 98.3%, respectively. High image quality with superb interobserver correlation (κ = 0.809 to > 0.999) validated the clinical feasibility of MDCT angiography for assessing AVFs. CONCLUSION. MDCT angiography is clinically feasible for evaluating the complete vascular tree of failing AVFs and in showing uncommon complications, including brachial aneurysms and central vein lesions.
AB - OBJECTIVE. The purpose of our study was to assess the clinical feasibility of MDCT angiography for evaluating hemodialysis arteriovenous fistulas (AVFs). MATERIALS AND METHODS. MDCT angiography of the complete vascular trees of 36 failing AVFs or AVF-related complications (20 native and 16 polytetrafluoroethylene graft AVFs) was reviewed. The numbers and degrees of stenoses at the anastomoses, graft loops, and draining and central veins and the presence of aneurysms or thrombosis were recorded. Wilcoxon's signed rank test was used to compare the findings of MDCT angiography with those of digital subtraction angiography (DSA) (n = 10), surgery (n = 22), or both (n = 4) performed within 2-6 days. Kappa statistics were used to correlate the clinical feasibility of MDCT angiography assessed by two reviewers. RESULTS. Among the 14 AVFs examined with both MDCT angiography and DSA, no significant difference was seen in the detection and grading (p = 0.317 to > 0.999) of stenoses at various segments of the entire vascular tree. Among the 36 AVFs examined, MDCT angiography also showed no significant difference from DSA or surgery in revealing vascular stenoses, aneurysms, and thromboses from the supplying artery to central veins (p = 0.317 to > 0.999). Overall, the sensitivity, specificity, positive and negative predictive values, and accuracy of MDCT angiography in lesion detection were 98.7%, 97.5%, 98.8%, 97.2%, and 98.3%, respectively. High image quality with superb interobserver correlation (κ = 0.809 to > 0.999) validated the clinical feasibility of MDCT angiography for assessing AVFs. CONCLUSION. MDCT angiography is clinically feasible for evaluating the complete vascular tree of failing AVFs and in showing uncommon complications, including brachial aneurysms and central vein lesions.
UR - http://www.scopus.com/inward/record.url?scp=33644847448&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=33644847448&partnerID=8YFLogxK
U2 - 10.2214/AJR.04.1553
DO - 10.2214/AJR.04.1553
M3 - Review article
C2 - 16247148
AN - SCOPUS:33644847448
SN - 0361-803X
VL - 185
SP - 1268
EP - 1274
JO - American Journal of Roentgenology
JF - American Journal of Roentgenology
IS - 5
ER -