TY - JOUR
T1 - Label-free, color-indicating, and sensitive biosensors of cholesteric liquid crystals on a single vertically aligned substrate
AU - Chen, Fu-Lun
AU - Fan, Yu-Jui
AU - Lin, Jia-De
AU - Hsiao, Yu-Cheng
N1 - © 2019 Optical Society of America under the terms of the OSA Open Access Publishing Agreement.
PY - 2019/9/1
Y1 - 2019/9/1
N2 - Biosensors based on liquid crystal (LC) materials can be made by employing the sensitive interfacial effect between LC molecules and alignment layers on substrates. In the past, the optical texture observation method was used in the LC biosensor field. However, the method is limited by a complicated fabrication process and quantitative reproducibility of results that bv evidence that both the reliability and accuracy of LC biosensors need to be improved. In this report, we demonstrate that cholesteric LC (CLC) cells in which one substrate is coated with a vertically aligned layer can be used as a new sensing technology. The chirality of the single vertically anchored (SVA)/CLC biosensor was tested by detecting bovine serum albumin (BSA), a protein standard commonly used in the lab. The colors and corresponding spectrum of the SVA/CLC biosensor changed with the BSA concentrations. A detection limit of 1 ng/ml was observed for the SVA/CLC biosensor. The linear optical properties of the SVA/CLC biosensor produced cheap, inexpensive, and color-indicating detection of biomolecules, and may promote the technology of point-of-care devices for disease-related biomarker detection.
AB - Biosensors based on liquid crystal (LC) materials can be made by employing the sensitive interfacial effect between LC molecules and alignment layers on substrates. In the past, the optical texture observation method was used in the LC biosensor field. However, the method is limited by a complicated fabrication process and quantitative reproducibility of results that bv evidence that both the reliability and accuracy of LC biosensors need to be improved. In this report, we demonstrate that cholesteric LC (CLC) cells in which one substrate is coated with a vertically aligned layer can be used as a new sensing technology. The chirality of the single vertically anchored (SVA)/CLC biosensor was tested by detecting bovine serum albumin (BSA), a protein standard commonly used in the lab. The colors and corresponding spectrum of the SVA/CLC biosensor changed with the BSA concentrations. A detection limit of 1 ng/ml was observed for the SVA/CLC biosensor. The linear optical properties of the SVA/CLC biosensor produced cheap, inexpensive, and color-indicating detection of biomolecules, and may promote the technology of point-of-care devices for disease-related biomarker detection.
UR - https://www.scopus.com/record/display.uri?eid=2-s2.0-85078694268&origin=inward&txGid=6e63aed358393f1cb135468b0406cc4e
U2 - 10.1364/BOE.10.004636
DO - 10.1364/BOE.10.004636
M3 - Article
C2 - 31565514
SN - 2156-7085
VL - 10
SP - 4636
EP - 4642
JO - Biomedical Optics Express
JF - Biomedical Optics Express
IS - 9
ER -