TY - JOUR
T1 - High amplitude bubble continuous positive airway pressure decreases lung injury in rats with ventilator-induced lung injury
AU - Wu, Chun-Shan
AU - Chou, Hsiu-Chu
AU - Huang, Liang-Ti
AU - Lin, Chun-Mao
AU - Lin, Yen-Kuang
AU - Chen, Chung-Ming
PY - 2019/10
Y1 - 2019/10
N2 - BACKGROUND: Bubble continuous positive airway pressure (BCPAP) has been used in neonates with respiratory distress for decades; however, the optimal setting for BCPAP circuits remains unknown. This study compared the gas exchange efficiency and lung protection efficacy between conventional and high-amplitude BCPAP devices. METHODS: We compared gas exchange, lung volume, and pulmonary inflammation severity among rats with ventilator-induced lung injury (VILI) that were treated with conventional BCPAP (BCPAP with an expiratory limb at 0°), high-amplitude BCPAP (BCPAP with an expiratory limb at 135°), or spontaneous breathing (SB). After mechanical ventilation for 90 minutes, the rats were randomly divided into four groups: a control group (euthanized immediately; n = 3), an SB group (n = 8), and two BCPAP groups that received BCPAP with the expiratory limb at either 0° (n = 8) or 135° (n = 7) for 90 minutes. RESULTS: The high-amplitude BCPAP group exhibited significantly lower alveolar protein, lung volume, and Interleukin-6 (IL-6) levels than did the SB group. The high-amplitude BCPAP group exhibited significantly lower IL-6 levels than did the conventional BCPAP group. The two BCPAP groups demonstrated no difference in gas exchange efficiency. CONCLUSION: High-amplitude BCPAP reduced lung inflammation and alveolar overdistension in rats with VILI after mechanical ventilation was ceased. Thus high-amplitude BCPAP may offer a superior lung protective effect than conventional BCPAP.
AB - BACKGROUND: Bubble continuous positive airway pressure (BCPAP) has been used in neonates with respiratory distress for decades; however, the optimal setting for BCPAP circuits remains unknown. This study compared the gas exchange efficiency and lung protection efficacy between conventional and high-amplitude BCPAP devices. METHODS: We compared gas exchange, lung volume, and pulmonary inflammation severity among rats with ventilator-induced lung injury (VILI) that were treated with conventional BCPAP (BCPAP with an expiratory limb at 0°), high-amplitude BCPAP (BCPAP with an expiratory limb at 135°), or spontaneous breathing (SB). After mechanical ventilation for 90 minutes, the rats were randomly divided into four groups: a control group (euthanized immediately; n = 3), an SB group (n = 8), and two BCPAP groups that received BCPAP with the expiratory limb at either 0° (n = 8) or 135° (n = 7) for 90 minutes. RESULTS: The high-amplitude BCPAP group exhibited significantly lower alveolar protein, lung volume, and Interleukin-6 (IL-6) levels than did the SB group. The high-amplitude BCPAP group exhibited significantly lower IL-6 levels than did the conventional BCPAP group. The two BCPAP groups demonstrated no difference in gas exchange efficiency. CONCLUSION: High-amplitude BCPAP reduced lung inflammation and alveolar overdistension in rats with VILI after mechanical ventilation was ceased. Thus high-amplitude BCPAP may offer a superior lung protective effect than conventional BCPAP.
UR - http://www.scopus.com/inward/record.url?scp=85072747581&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85072747581&partnerID=8YFLogxK
U2 - 10.1097/JCMA.0000000000000070
DO - 10.1097/JCMA.0000000000000070
M3 - Article
C2 - 30893255
SN - 1726-4901
VL - 82
SP - 795
EP - 801
JO - Journal of the Chinese Medical Association
JF - Journal of the Chinese Medical Association
IS - 10
ER -