TY - JOUR
T1 - Factors Affecting Optimal Aortic Remodeling After Thoracic Endovascular Aortic Repair of Type B (IIIb) Aortic Dissection
AU - Chen, I. Ming
AU - Chen, Po Lin
AU - Huang, Chun Yang
AU - Weng, Shih Hsien
AU - Chen, Wei Yuan
AU - Shih, Chun Che
N1 - Publisher Copyright:
© 2017, Springer Science+Business Media New York and the Cardiovascular and Interventional Radiological Society of Europe (CIRSE).
PY - 2017/5/1
Y1 - 2017/5/1
N2 - Purpose: The purpose of this study was to determine factors associated with entire aortic remodeling after thoracic endovascular aortic repair (TEVAR) in patients with type B dissection. Materials and Methods: The patients with type B (IIIb) dissections who underwent TEVAR from 2006 to 2013 with minimum of 2 years of follow-up computed tomography data were retrospectively reviewed. Based on the status of false lumen remodeling of entire aorta, patients were divided into three groups: complete regression, total thrombosis, and inadequate regression with patent abdominal false lumen. Results: A total of 90 patients (72 males, 18 females; mean age 56.6 ± 16.4 years) were included and divided into the complete regression (n = 22), total thrombosis (n = 18), and inadequate regression (n = 50) groups. Multivariate logistic regression analysis indicated that dissection extension to iliac arteries, increased preoperative number of dissection tear over abdominal aorta, and decreased preoperative abdominal aorta bifurcation true lumen ratio, as compared between the inadequate and complete regression groups, were associated with a persistent false lumen (odds ratio = 33.33, 2.304, and 0.021; all, p ≤ 0.012). Comparison of 6, 12, and 24 months postoperative data revealed no significant differences at any level, suggesting that the true lumen area ratio might not change after 6 months postoperatively. Conclusions: Increased preoperative numbers of dissection tear around the abdominal visceral branches, dissection extension to the iliac arteries, and decreased preoperative true lumen area ratio of abdominal aorta are predictive of entire aortic remodeling after TEVAR in patients with type B dissection. Level of Evidence: III.
AB - Purpose: The purpose of this study was to determine factors associated with entire aortic remodeling after thoracic endovascular aortic repair (TEVAR) in patients with type B dissection. Materials and Methods: The patients with type B (IIIb) dissections who underwent TEVAR from 2006 to 2013 with minimum of 2 years of follow-up computed tomography data were retrospectively reviewed. Based on the status of false lumen remodeling of entire aorta, patients were divided into three groups: complete regression, total thrombosis, and inadequate regression with patent abdominal false lumen. Results: A total of 90 patients (72 males, 18 females; mean age 56.6 ± 16.4 years) were included and divided into the complete regression (n = 22), total thrombosis (n = 18), and inadequate regression (n = 50) groups. Multivariate logistic regression analysis indicated that dissection extension to iliac arteries, increased preoperative number of dissection tear over abdominal aorta, and decreased preoperative abdominal aorta bifurcation true lumen ratio, as compared between the inadequate and complete regression groups, were associated with a persistent false lumen (odds ratio = 33.33, 2.304, and 0.021; all, p ≤ 0.012). Comparison of 6, 12, and 24 months postoperative data revealed no significant differences at any level, suggesting that the true lumen area ratio might not change after 6 months postoperatively. Conclusions: Increased preoperative numbers of dissection tear around the abdominal visceral branches, dissection extension to the iliac arteries, and decreased preoperative true lumen area ratio of abdominal aorta are predictive of entire aortic remodeling after TEVAR in patients with type B dissection. Level of Evidence: III.
KW - Aortic dissection
KW - False lumen
KW - Remodeling
KW - Stanford type B
KW - TEVAR
UR - http://www.scopus.com/inward/record.url?scp=85010720867&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85010720867&partnerID=8YFLogxK
U2 - 10.1007/s00270-017-1563-y
DO - 10.1007/s00270-017-1563-y
M3 - Article
C2 - 28116473
AN - SCOPUS:85010720867
SN - 0174-1551
VL - 40
SP - 671
EP - 681
JO - CardioVascular and Interventional Radiology
JF - CardioVascular and Interventional Radiology
IS - 5
ER -