TY - JOUR
T1 - Enantioselective and simultaneous determination of lactate and 3-hydroxybutyrate in human plasma and urine using a narrow-bore online two-dimensional high-performance liquid chromatography system
AU - Hsieh, Chin Ling
AU - Koga, Reiko
AU - Furusho, Aogu
AU - Akita, Takeyuki
AU - Mita, Masashi
AU - Ide, Tomomi
AU - Lee, Jen Ai
AU - Hamase, Kenji
N1 - Funding Information:
The authors appreciate Shiseido Co., Ltd. (Tokyo, Japan) for their technical support on the 2D-HPLC system. This work was partly supported by JSPS KAKENHI grant number 16H05080.
Publisher Copyright:
© 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim
PY - 2018/3
Y1 - 2018/3
N2 - For the enantioselective and simultaneous analysis of lactate and 3-hydroxybutyrate, a validated online two-dimensional high-performance liquid chromatography system using 4-nitro-7-piperazino-2,1,3-benzoxadiazole as a fluorescent derivatization reagent has been developed. For the reversed-phase separation in the first dimension, a Capcell Pak C18 ACR column (1.5 × 250 mm, particle size 3 μm) was used, and the target fractions were isolated by their hydrophobicity. In the second dimension, a polysaccharide-coated enantioselective column, Chiralpak AD-H (2.0 × 250 mm, 5 μm), was used. The system was validated by the calibration curve, intraday precision, interday precision, and accuracy using standards and real human samples, and satisfactory results were obtained. The present method was applied to human plasma and urine, and in the plasma, trace amounts of d-lactate (8.4 μM) and l-3-hydroxybutyrate (1.0 μM), besides high levels of l-lactate (860.9 μM) and d-3-hydroxybutyrate (59.4 μM), were successfully determined. In urine, trace levels of d-lactate (3.7 μM), d-3-hydroxybutyrate (2.3 μM), and l-3-hydroxybutyrate (3.3 μM) in addition to a relatively large amount of l-lactate (15.4 μM) were observed. The present online two-dimensional high-performance liquid chromatography system is useful for the simultaneous determination of all the lactate and 3-hydroxybutyrate enantiomers in human physiological fluids, and further clinical applications are ongoing.
AB - For the enantioselective and simultaneous analysis of lactate and 3-hydroxybutyrate, a validated online two-dimensional high-performance liquid chromatography system using 4-nitro-7-piperazino-2,1,3-benzoxadiazole as a fluorescent derivatization reagent has been developed. For the reversed-phase separation in the first dimension, a Capcell Pak C18 ACR column (1.5 × 250 mm, particle size 3 μm) was used, and the target fractions were isolated by their hydrophobicity. In the second dimension, a polysaccharide-coated enantioselective column, Chiralpak AD-H (2.0 × 250 mm, 5 μm), was used. The system was validated by the calibration curve, intraday precision, interday precision, and accuracy using standards and real human samples, and satisfactory results were obtained. The present method was applied to human plasma and urine, and in the plasma, trace amounts of d-lactate (8.4 μM) and l-3-hydroxybutyrate (1.0 μM), besides high levels of l-lactate (860.9 μM) and d-3-hydroxybutyrate (59.4 μM), were successfully determined. In urine, trace levels of d-lactate (3.7 μM), d-3-hydroxybutyrate (2.3 μM), and l-3-hydroxybutyrate (3.3 μM) in addition to a relatively large amount of l-lactate (15.4 μM) were observed. The present online two-dimensional high-performance liquid chromatography system is useful for the simultaneous determination of all the lactate and 3-hydroxybutyrate enantiomers in human physiological fluids, and further clinical applications are ongoing.
KW - 3-hydroxybutyrate
KW - chiral stationary phases
KW - enantiomer separation
KW - lactate
KW - two-dimensional high-performance liquid chromatography
UR - http://www.scopus.com/inward/record.url?scp=85041591165&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85041591165&partnerID=8YFLogxK
U2 - 10.1002/jssc.201701283
DO - 10.1002/jssc.201701283
M3 - Article
AN - SCOPUS:85041591165
SN - 1615-9306
VL - 41
SP - 1298
EP - 1306
JO - Journal of Separation Science
JF - Journal of Separation Science
IS - 6
ER -