TY - JOUR
T1 - Effect of different designs of interspinous process devices on the instrumented and adjacent levels after double-level lumbar decompression surgery
T2 - A finite element analysis
AU - Lo, Hao Ju
AU - Chen, Hung Ming
AU - Kuo, Yi Jie
AU - Yang, Sai Wei
N1 - Publisher Copyright:
Copyright: © 2020 Lo et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
PY - 2020/12
Y1 - 2020/12
N2 - Recently, various designs and material manufactured interspinous process devices (IPDs) are on the market in managing symptomatic lumbar spinal stenosis (LSS). However, atraumatic fracture of the intervening spinous process has been reported in patients, particularly, double or multiple level lumbar decompression surgery with IPDs. This study aimed to bio-mechanically investigate the effects of few commercial IPDs, namely DIAMTM, CoflexTM, and M-PEEK, which were implanted into the L2-3, L3-4 double-level lumbar spinal processes. A validated finite element model of musculoskeletal intact lumbar spinal column was modified to accommodate the numerical analysis of different implants. The range of motion (ROM) between each vertebra, stiffness of the implanted level, intra stress on the intervertebral discs and facet joints, and the contact forces on spinous processes were compared. Among the three implants, the Coflex system showed the largest ROM restriction in extension and caused the highest stress over the disc annulus at the adjacent levels, as well as the sandwich phenomenon on the spinous process at the instrumented levels. Further, the DIAM device provided a superior loading-sharing between the two bridge supports, and the M-PEEK system offered a superior load-sharing from the superior spinous process to the lower pedicle screw. The limited motion at the instrumented segments were compensated by the upper and lower adjacent functional units, however, this increasing ROM and stress would accelerate the degeneration of un-instrumented segments.
AB - Recently, various designs and material manufactured interspinous process devices (IPDs) are on the market in managing symptomatic lumbar spinal stenosis (LSS). However, atraumatic fracture of the intervening spinous process has been reported in patients, particularly, double or multiple level lumbar decompression surgery with IPDs. This study aimed to bio-mechanically investigate the effects of few commercial IPDs, namely DIAMTM, CoflexTM, and M-PEEK, which were implanted into the L2-3, L3-4 double-level lumbar spinal processes. A validated finite element model of musculoskeletal intact lumbar spinal column was modified to accommodate the numerical analysis of different implants. The range of motion (ROM) between each vertebra, stiffness of the implanted level, intra stress on the intervertebral discs and facet joints, and the contact forces on spinous processes were compared. Among the three implants, the Coflex system showed the largest ROM restriction in extension and caused the highest stress over the disc annulus at the adjacent levels, as well as the sandwich phenomenon on the spinous process at the instrumented levels. Further, the DIAM device provided a superior loading-sharing between the two bridge supports, and the M-PEEK system offered a superior load-sharing from the superior spinous process to the lower pedicle screw. The limited motion at the instrumented segments were compensated by the upper and lower adjacent functional units, however, this increasing ROM and stress would accelerate the degeneration of un-instrumented segments.
UR - http://www.scopus.com/inward/record.url?scp=85098984421&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85098984421&partnerID=8YFLogxK
U2 - 10.1371/journal.pone.0244571
DO - 10.1371/journal.pone.0244571
M3 - Article
C2 - 33378405
AN - SCOPUS:85098984421
SN - 1932-6203
VL - 15
JO - PLoS ONE
JF - PLoS ONE
IS - 12 December
M1 - e0244571
ER -