TY - JOUR
T1 - Effect of bracket slot and archwire dimensions on anterior tooth movement during space closure in sliding mechanics
T2 - A 3-dimensional finite element study
AU - Tominaga, Jun Ya
AU - Ozaki, Hiroya
AU - Chiang, Pao Chang
AU - Sumi, Mayumi
AU - Tanaka, Motohiro
AU - Koga, Yoshiyuki
AU - Bourauel, Christoph
AU - Yoshida, Noriaki
PY - 2014/1/1
Y1 - 2014/1/1
N2 - Introduction It has been found that controlled movement of the anterior teeth can be obtained by attaching a certain length of power arm onto an archwire in sliding mechanics. However, the impact of the archwire/bracket play on anterior tooth movement has not been clarified. The purpose of this study was to compare the effect of the power arm on anterior tooth movements with different dimensions of bracket slots and archwires. Methods A 3-dimensional finite element method was used to simulate en-masse anterior tooth retraction in sliding mechanics. Displacements of the maxillary central incisor and the archwire deformation were calculated when applying retraction forces from different lengths of power arms. Results When a 0.017 × 0.022-in archwire was engaged into the 0.018-in slot bracket, bodily movement of the incisor was obtained with 9.1-mm length of the power arm. When a 0.022-in slot system was coupled with a 0.019 × 0.025-in archwire, bodily movement was observed with a power arm length of 11.6 mm. Conclusions Archwire/bracket play has a remarkable impact on anterior tooth movement. An effective torque application to the anterior teeth becomes clinically difficult in sliding mechanics combined with power arms when the archwire/bracket play is large.
AB - Introduction It has been found that controlled movement of the anterior teeth can be obtained by attaching a certain length of power arm onto an archwire in sliding mechanics. However, the impact of the archwire/bracket play on anterior tooth movement has not been clarified. The purpose of this study was to compare the effect of the power arm on anterior tooth movements with different dimensions of bracket slots and archwires. Methods A 3-dimensional finite element method was used to simulate en-masse anterior tooth retraction in sliding mechanics. Displacements of the maxillary central incisor and the archwire deformation were calculated when applying retraction forces from different lengths of power arms. Results When a 0.017 × 0.022-in archwire was engaged into the 0.018-in slot bracket, bodily movement of the incisor was obtained with 9.1-mm length of the power arm. When a 0.022-in slot system was coupled with a 0.019 × 0.025-in archwire, bodily movement was observed with a power arm length of 11.6 mm. Conclusions Archwire/bracket play has a remarkable impact on anterior tooth movement. An effective torque application to the anterior teeth becomes clinically difficult in sliding mechanics combined with power arms when the archwire/bracket play is large.
UR - http://www.scopus.com/inward/record.url?scp=84904962691&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84904962691&partnerID=8YFLogxK
U2 - 10.1016/j.ajodo.2014.04.016
DO - 10.1016/j.ajodo.2014.04.016
M3 - Article
C2 - 25085299
AN - SCOPUS:84904962691
SN - 0889-5406
VL - 146
SP - 166
EP - 174
JO - American Journal of Orthodontics and Dentofacial Orthopedics
JF - American Journal of Orthodontics and Dentofacial Orthopedics
IS - 2
ER -