TY - JOUR
T1 - CT angiography findings predictive of kidney injury in chronic aortic dissection
AU - Kuo, Tzu Ting
AU - Chen, Po Lin
AU - Huang, Chun Yang
AU - Chen, I. Ming
AU - Shih, Chun Che
N1 - Funding Information:
Supported by grants MOST105-2314-B-010-048-MY3, MOST105-2314-B-075-006, and MOST 106-2314-B-101-056 from the National Science Council, Taiwan, and grants VGH-104-C-117, VGH-105C-101, VGH-V106B-022, VGH-V106D24-004-MY2-1, VGH-V106D24-004-MY2-2, VGH-V107B-002, VGH-107C-147, VGH-V105D18-001-MY3-3 from Taipei Veterans General Hospital, Taiwan.
Publisher Copyright:
© American Roentgen Ray Society.
PY - 2020/6
Y1 - 2020/6
N2 - OBJECTIVE: The purpose of this study was to compare the volume alteration and effective renal plasma flow of kidneys supplied by false lumens (FLs) with those of kidneys supplied by true lumens (TLs), to show the discrepancy in perfusion between the two lumens. We sought to corroborate malperfusion of FL-supplied kidneys with imaging characteristics observed on CT angiography. MATERIALS AND METHODS: A retrospective analysis was conducted using prospectively collected data for 87 patients with a diagnosis of residual chronic aortic dissection between 2005 and 2013 who had one kidney perfused by a TL and the other kidney perfused by a FL. RESULTS: Overall, at follow-up, FL-supplied kidneys had a mean (± SD) effective renal plasma flow (117.5 ± 42.6 vs 146.6 ± 41.0 mL/min; p = 0.004) and volume (131.1 ± 37.1 vs 146.5 ± 33.3 cm3; p = 0.004) that were lower than those of TL-supplied kidneys. Multivariate analysis revealed the presence of a proximal major inlet (odds ratio, 0.306; 95% CI, 0.103-0.910; p = 0.033) and large FL area (odds ratio, 0.104; CI, 0.012-0.880; p = 0.038) as factors protecting against malperfusion of FL-supplied kidneys. In patients with dissected renal arteries, the FL-supplied kidney had low effective renal plasma flow (mean, 88.5 ± 26.8 vs 149.6 ± 43.5 mL/min; p = 0.004) and diminished volume (mean, 120.4 ± 30.4 vs 152.3 ± 24.6 cm3; p = 0.001). CONCLUSION: In the present study, kidneys perfused by FLs showed decreased volume and reduced effective renal plasma flow during follow-up, particularly those kidneys with dissected renal arteries, a small FL area at the renal level, and lack of a proximal major inlet. Further studies are warranted to identify the clinical relevance of malperfusion in FL-supplied kidneys.
AB - OBJECTIVE: The purpose of this study was to compare the volume alteration and effective renal plasma flow of kidneys supplied by false lumens (FLs) with those of kidneys supplied by true lumens (TLs), to show the discrepancy in perfusion between the two lumens. We sought to corroborate malperfusion of FL-supplied kidneys with imaging characteristics observed on CT angiography. MATERIALS AND METHODS: A retrospective analysis was conducted using prospectively collected data for 87 patients with a diagnosis of residual chronic aortic dissection between 2005 and 2013 who had one kidney perfused by a TL and the other kidney perfused by a FL. RESULTS: Overall, at follow-up, FL-supplied kidneys had a mean (± SD) effective renal plasma flow (117.5 ± 42.6 vs 146.6 ± 41.0 mL/min; p = 0.004) and volume (131.1 ± 37.1 vs 146.5 ± 33.3 cm3; p = 0.004) that were lower than those of TL-supplied kidneys. Multivariate analysis revealed the presence of a proximal major inlet (odds ratio, 0.306; 95% CI, 0.103-0.910; p = 0.033) and large FL area (odds ratio, 0.104; CI, 0.012-0.880; p = 0.038) as factors protecting against malperfusion of FL-supplied kidneys. In patients with dissected renal arteries, the FL-supplied kidney had low effective renal plasma flow (mean, 88.5 ± 26.8 vs 149.6 ± 43.5 mL/min; p = 0.004) and diminished volume (mean, 120.4 ± 30.4 vs 152.3 ± 24.6 cm3; p = 0.001). CONCLUSION: In the present study, kidneys perfused by FLs showed decreased volume and reduced effective renal plasma flow during follow-up, particularly those kidneys with dissected renal arteries, a small FL area at the renal level, and lack of a proximal major inlet. Further studies are warranted to identify the clinical relevance of malperfusion in FL-supplied kidneys.
KW - Aortic dissection
KW - Effective renal plasma flow
KW - Kidney perfusion
KW - Malperfusion
KW - Renal function
UR - http://www.scopus.com/inward/record.url?scp=85085534077&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85085534077&partnerID=8YFLogxK
U2 - 10.2214/AJR.19.21877
DO - 10.2214/AJR.19.21877
M3 - Article
C2 - 32286876
AN - SCOPUS:85085534077
SN - 0361-803X
VL - 214
SP - 1409
EP - 1416
JO - American Journal of Roentgenology
JF - American Journal of Roentgenology
IS - 6
ER -