T1 - Continuous improvement in Mandarin lexical tone perception as the number of channels increased
T2 - A simulation study of cochlear implant
AU - Lin, Yong-Song
AU - Lee, Fei Peng
AU - Huang, I. Shun
AU - Peng, Shu Chen
PY - 2007
Y1 - 2007
N2 - Conclusion. With reference to English phoneme recognition, where performance usually does not improve after six or eight channels in cochlear implants (CIs), increasing total channel numbers continuously improved perception of Mandarin tones. Objective. To test our hypothesis that current CI strategies might be modified to improve Mandarin lexical tonal perception. Materials and methods. Lexical tonal perception tests using 48 monosyllables in Mandarin Chinese were conducted in 32 native Mandarin speakers with normal hearing. The performance of tonal perception was compared among the controlled factors, which were total channel number, number of channels allocated to the F0 spectrum, and whether there were spectral shifts in the electrode configuration. The experimental condition that preserves fine structure was used as a comparison. Results. The signal processing strategy using 16 channels - which is technically possible with current CI devices - produced better tonal perception than those using 12 or 8 channels. Increasing the number of fundamental channels did not improve tonal perception, and spectral shifts did not change tonal perception. An experimental condition (FiC12) that preserves the fine structure produced significantly better overall scores for tone perception than other experimental conditions with envelope strategies.
AB - Conclusion. With reference to English phoneme recognition, where performance usually does not improve after six or eight channels in cochlear implants (CIs), increasing total channel numbers continuously improved perception of Mandarin tones. Objective. To test our hypothesis that current CI strategies might be modified to improve Mandarin lexical tonal perception. Materials and methods. Lexical tonal perception tests using 48 monosyllables in Mandarin Chinese were conducted in 32 native Mandarin speakers with normal hearing. The performance of tonal perception was compared among the controlled factors, which were total channel number, number of channels allocated to the F0 spectrum, and whether there were spectral shifts in the electrode configuration. The experimental condition that preserves fine structure was used as a comparison. Results. The signal processing strategy using 16 channels - which is technically possible with current CI devices - produced better tonal perception than those using 12 or 8 channels. Increasing the number of fundamental channels did not improve tonal perception, and spectral shifts did not change tonal perception. An experimental condition (FiC12) that preserves the fine structure produced significantly better overall scores for tone perception than other experimental conditions with envelope strategies.
KW - Cochlear implant
KW - Fine structure
KW - Frequency allocation
KW - Mandarin lexical tone
KW - Tonal perception
UR - http://www.scopus.com/inward/record.url?scp=34247390520&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=34247390520&partnerID=8YFLogxK
U2 - 10.1080/00016480600951434
DO - 10.1080/00016480600951434
M3 - Article
C2 - 17453477
AN - SCOPUS:34247390520
SN - 0001-6489
VL - 127
SP - 505
EP - 514
JO - Acta Oto-Laryngologica
JF - Acta Oto-Laryngologica
IS - 5
ER -