T1 - Comparisons of predictive performance of breathing pattern variability measured during T-piece, automatic tube compensation, and pressure support ventilation for weaning intensive care unit patients from mechanical ventilation
AU - Bien, Mauo-Ying
AU - Shui Lin, You
AU - Shih, Chung-Hung
AU - Yang, You-Lan
AU - Lin, Hui Wen
AU - Bai, Kuan-Jen
AU - Wang, Jia Horng
AU - Kou, Yu Ru
PY - 2011/10
Y1 - 2011/10
N2 - Objective: To investigate the influence of different ventilatory supports on the predictive performance of breathing pattern variability for extubation outcomes in intensive care unit patients. Design and Setting: A prospective measurement of retrospectively analyzed breathing pattern variability in a medical center. Patients: Sixty-eight consecutive and ready-for-weaning patients were divided into success (n = 45) and failure (n = 23) groups based on their extubation outcomes. Measurements: Breath-to-breath analyses of peak inspiratory flow, total breath duration, tidal volume, and rapid shallow breathing index were performed for three 30-min periods while patients randomly received T-piece, 100% inspiratory automatic tube compensation with 5 cm H2O positive end-expiratory pressure, and 5 cm H2O pressure support ventilation with 5 cm H2O positive end-expiratory pressure trials. Coefficient of variations and data dispersion (standard descriptor values SD1 and SD2 of the Poincaré plot) were analyzed to serve as breathing pattern variability indices. MAIN RESULTS:: Under all three trials, breathing pattern variability in extubation failure patients was smaller than in extubation success patients. Compared to the T-piece trial, 100% inspiratory automatic tube compensation with 5 cm H2O positive end-expiratory pressure and 5 cm H2O pressure support ventilation with 5 cm H2O positive end-expiratory pressure decreased the ability of certain breathing pattern variability indices to discriminate extubation success from extubation failure. The areas under the receiver operating characteristic curve of these breathing pattern variability indices were: T-piece (0.73-0.87) > 100% inspiratory automatic tube compensation with 5 cm H2O positive end-expiratory pressure (0.60-0.79) > 5 cm H2O pressure support ventilation with 5 cm H2O positive end-expiratory pressure (0.53-0.76). Analysis of the classification and regression tree indicated that during the T-piece trial, a SD1 of peak inspiratory flow >3.36 L/min defined a group including all extubation success patients. Conversely, the combination of a SD1 of peak inspiratory flow ≤3.36 L/min and a coefficient of variations of rapid shallow breathing index ≤0.23 defined a group of all extubation failure patients. The decision strategies using SD1 of peak inspiratory flow and coefficient of variations of rapid shallow breathing index measured during 100% inspiratory automatic tube compensation with 5 cm H2O positive end-expiratory pressure and 5 cm H2O pressure support ventilation with 5 cm H2O positive end-expiratory pressure trials achieved a less clear separation of extubation failure from extubation success. Conclusions: Since 100% inspiratory automatic tube compensation with 5 cm H2O positive end-expiratory pressure and 5 cm H2O pressure support ventilation with 5 cm H2O positive end-expiratory pressure reduce the predictive performance of breathing pattern variability, breathing pattern variability measurement during the T-piece trial is the best choice for predicting extubation outcome in intensive care unit patients patients.
AB - Objective: To investigate the influence of different ventilatory supports on the predictive performance of breathing pattern variability for extubation outcomes in intensive care unit patients. Design and Setting: A prospective measurement of retrospectively analyzed breathing pattern variability in a medical center. Patients: Sixty-eight consecutive and ready-for-weaning patients were divided into success (n = 45) and failure (n = 23) groups based on their extubation outcomes. Measurements: Breath-to-breath analyses of peak inspiratory flow, total breath duration, tidal volume, and rapid shallow breathing index were performed for three 30-min periods while patients randomly received T-piece, 100% inspiratory automatic tube compensation with 5 cm H2O positive end-expiratory pressure, and 5 cm H2O pressure support ventilation with 5 cm H2O positive end-expiratory pressure trials. Coefficient of variations and data dispersion (standard descriptor values SD1 and SD2 of the Poincaré plot) were analyzed to serve as breathing pattern variability indices. MAIN RESULTS:: Under all three trials, breathing pattern variability in extubation failure patients was smaller than in extubation success patients. Compared to the T-piece trial, 100% inspiratory automatic tube compensation with 5 cm H2O positive end-expiratory pressure and 5 cm H2O pressure support ventilation with 5 cm H2O positive end-expiratory pressure decreased the ability of certain breathing pattern variability indices to discriminate extubation success from extubation failure. The areas under the receiver operating characteristic curve of these breathing pattern variability indices were: T-piece (0.73-0.87) > 100% inspiratory automatic tube compensation with 5 cm H2O positive end-expiratory pressure (0.60-0.79) > 5 cm H2O pressure support ventilation with 5 cm H2O positive end-expiratory pressure (0.53-0.76). Analysis of the classification and regression tree indicated that during the T-piece trial, a SD1 of peak inspiratory flow >3.36 L/min defined a group including all extubation success patients. Conversely, the combination of a SD1 of peak inspiratory flow ≤3.36 L/min and a coefficient of variations of rapid shallow breathing index ≤0.23 defined a group of all extubation failure patients. The decision strategies using SD1 of peak inspiratory flow and coefficient of variations of rapid shallow breathing index measured during 100% inspiratory automatic tube compensation with 5 cm H2O positive end-expiratory pressure and 5 cm H2O pressure support ventilation with 5 cm H2O positive end-expiratory pressure trials achieved a less clear separation of extubation failure from extubation success. Conclusions: Since 100% inspiratory automatic tube compensation with 5 cm H2O positive end-expiratory pressure and 5 cm H2O pressure support ventilation with 5 cm H2O positive end-expiratory pressure reduce the predictive performance of breathing pattern variability, breathing pattern variability measurement during the T-piece trial is the best choice for predicting extubation outcome in intensive care unit patients patients.
KW - breathing pattern variability
KW - classification and regression tree analysis
KW - receiver operating characteristic curve
KW - spontaneous breathing trial
KW - weaning predictor
UR - http://www.scopus.com/inward/record.url?scp=80052969792&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=80052969792&partnerID=8YFLogxK
U2 - 10.1097/CCM.0b013e31822279ed
DO - 10.1097/CCM.0b013e31822279ed
M3 - Article
C2 - 21666447
AN - SCOPUS:80052969792
SN - 0090-3493
VL - 39
SP - 2253
EP - 2262
JO - Critical Care Medicine
JF - Critical Care Medicine
IS - 10
ER -