TY - JOUR
T1 - Comparison of oral glucose insulin sensitivity with other insulin sensitivity surrogates from oral glucose tolerance tests in Chinese
AU - Wu, Chung Ze
AU - Pei, Dee
AU - Su, Ching Chieh
AU - Hsiao, Fone Ching
AU - Chu, Yi Min
AU - Lee, Li Hsiu
AU - Wang, Kun
AU - Hsieh, An Tsz
AU - Lin, Juinn Diann
AU - Hsia, Te Lin
PY - 2010/1
Y1 - 2010/1
N2 - Introduction: There is no single method of measuring insulin resistance that is both accurate and can be easily performed by general researchers. We validate the accuracy of oral glucose insulin sensitivity (OGIS) in the Chinese by comparing the OGIS120 and OGIS180, homeostasis model assessment of insulin resistance (HOMA-IR), and quantitative insulin sensitivity check index (OUICKI) with steady-state plasma glucose (SSPG) in different glucose tolerance subjects. Materials and Methods: We enrolled 515 subjects, aged between 20 and 75 years old, during routine health evaluations. All subjects were divided into normal, obese, impaired fasting glucose (IFG), impaired glucose tolerance (IGT) and type 2 diabetes (T2D) groups. Participants had a 3-hour oral glucose tolerance test (OGTT) and SSPG with an insulin suppression test. The relationships between SSPG and OGIS120, OGIS180, HOMA-IR, and QUICKI were evaluated. Results: The normal group had the highest OGIS120, OGIS180 and lowest SSPG as compared with the other 4 groups. OGIS180, HOMA-IR and QUICKI in all 5 groups were significantly related to SSPG (r = 0.397-0.621, all P 120 in all 5 groups was not significantly related to SSPG (r = 0.003-0.226). Additionally, the r value of OGIS180 against SSPG was not higher than the other 2 insulin sensitivity surrogates from OGTT. Conclusions: Although OGIS180 was more accurate in estimating insulin sensitivity than OGIS120 in the Chinese, it was not superior to the traditional surrogates such as HOMA-IR or QUICKI.
AB - Introduction: There is no single method of measuring insulin resistance that is both accurate and can be easily performed by general researchers. We validate the accuracy of oral glucose insulin sensitivity (OGIS) in the Chinese by comparing the OGIS120 and OGIS180, homeostasis model assessment of insulin resistance (HOMA-IR), and quantitative insulin sensitivity check index (OUICKI) with steady-state plasma glucose (SSPG) in different glucose tolerance subjects. Materials and Methods: We enrolled 515 subjects, aged between 20 and 75 years old, during routine health evaluations. All subjects were divided into normal, obese, impaired fasting glucose (IFG), impaired glucose tolerance (IGT) and type 2 diabetes (T2D) groups. Participants had a 3-hour oral glucose tolerance test (OGTT) and SSPG with an insulin suppression test. The relationships between SSPG and OGIS120, OGIS180, HOMA-IR, and QUICKI were evaluated. Results: The normal group had the highest OGIS120, OGIS180 and lowest SSPG as compared with the other 4 groups. OGIS180, HOMA-IR and QUICKI in all 5 groups were significantly related to SSPG (r = 0.397-0.621, all P 120 in all 5 groups was not significantly related to SSPG (r = 0.003-0.226). Additionally, the r value of OGIS180 against SSPG was not higher than the other 2 insulin sensitivity surrogates from OGTT. Conclusions: Although OGIS180 was more accurate in estimating insulin sensitivity than OGIS120 in the Chinese, it was not superior to the traditional surrogates such as HOMA-IR or QUICKI.
KW - Homeostasis model assessment
KW - Insulin resistance
KW - Quantitative insulin sensitivity check index
UR - http://www.scopus.com/inward/record.url?scp=75749093433&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=75749093433&partnerID=8YFLogxK
M3 - Article
C2 - 20126806
AN - SCOPUS:75749093433
SN - 0304-4602
VL - 39
SP - 4
EP - 8
JO - Annals of the Academy of Medicine Singapore
JF - Annals of the Academy of Medicine Singapore
IS - 1
ER -