N2 - Background: Colonoscopy is considered the most effective method for diagnosing colorectal diseases, but its application is sometimes limited due to invasiveness, patient intolerance, and the need for sedation. Objective: The aim of this study was to improve the problem of loop formation and shorten the cecal intubation time of colonoscopy by using a magnetic control system (MCS). Methods: Two experienced gastroenterologists, three trainees, and a novice repeated colonoscopy without or with MCS on three colonoscopy training model simulator cases. These cases were divided into introductory (case 2) and challenging levels (cases 4 and 5). The cecal intubation times were recorded. Results: For all cases, the average cecal intubation times for the experienced gastroenterologists with MCS were significantly shorter than without MCS (case 2: 52.45 vs. 27.65 s, p < 0.001; case 4: 166.7 vs. 120.55 s, p < 0.01; case 5: 130.35 vs. 100.2 s, p < 0.05). Those of the trainees also revealed significantly shorter times with MCS (case 2: 67.27 vs. 51 s, p < 0.01; case 4: 253.27 vs. 170.97 s, p < 0.001; case 5: 144.1 vs. 85.57 s, p < 0.001). Conclusion: Conducting colonoscopy with MCS is safe and smooth, and shortens the cecal intubation time by navigating the forepart of the colonoscope. In addition, all diagnostic and therapeutic benefits of conventional colonoscopy are retained.
AB - Background: Colonoscopy is considered the most effective method for diagnosing colorectal diseases, but its application is sometimes limited due to invasiveness, patient intolerance, and the need for sedation. Objective: The aim of this study was to improve the problem of loop formation and shorten the cecal intubation time of colonoscopy by using a magnetic control system (MCS). Methods: Two experienced gastroenterologists, three trainees, and a novice repeated colonoscopy without or with MCS on three colonoscopy training model simulator cases. These cases were divided into introductory (case 2) and challenging levels (cases 4 and 5). The cecal intubation times were recorded. Results: For all cases, the average cecal intubation times for the experienced gastroenterologists with MCS were significantly shorter than without MCS (case 2: 52.45 vs. 27.65 s, p < 0.001; case 4: 166.7 vs. 120.55 s, p < 0.01; case 5: 130.35 vs. 100.2 s, p < 0.05). Those of the trainees also revealed significantly shorter times with MCS (case 2: 67.27 vs. 51 s, p < 0.01; case 4: 253.27 vs. 170.97 s, p < 0.001; case 5: 144.1 vs. 85.57 s, p < 0.001). Conclusion: Conducting colonoscopy with MCS is safe and smooth, and shortens the cecal intubation time by navigating the forepart of the colonoscope. In addition, all diagnostic and therapeutic benefits of conventional colonoscopy are retained.
KW - Cecal intubation time
KW - Colonoscopy
KW - Magnet
UR - http://www.scopus.com/inward/record.url?scp=84906937754&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84906937754&partnerID=8YFLogxK
U2 - 10.1007/s00464-014-3460-7
DO - 10.1007/s00464-014-3460-7
M3 - Article
C2 - 24648105
AN - SCOPUS:84906937754
SN - 0930-2794
VL - 28
SP - 2480
EP - 2483
JO - Surgical endoscopy
JF - Surgical endoscopy
IS - 8
ER -