TY - JOUR
T1 - Clinical results of hamstring autografts in anterior cruciate ligament reconstruction
T2 - A comparison of femoral knot/press-fit fixation and interference screw fixation
AU - Ho, Wei Pin
AU - Lee, Chian Her
AU - Huang, Chang Hung
AU - Chen, Chih Hwa
AU - Chuang, Tai Yuan
PY - 2014/7
Y1 - 2014/7
N2 - Purpose To compare the clinical outcomes of femoral knot/press-fit anterior cruciate ligament (ACL) reconstruction with conventional techniques using femoral interference screws. Methods Among patients who underwent arthroscopic ACL reconstruction with hamstring autografts, 73 were treated with either a femoral knot/press-fit technique (40 patients, group A) or femoral interference screw fixation (33 patients, group B). The clinical results of the 2 groups were retrospectively compared. The inclusion criteria were primary ACL reconstruction in active patients. The exclusion criteria were fractures, multiligamentous injuries, patients undergoing revision, or patients with contralateral ACL-deficient knees. In the femoral knot/press-fit technique, semitendinosus and gracilis tendons were prepared as 2 loops with knots. After passage through a bottleneck femoral tunnel, the grafts were fixed with a press-fit method (grafts' knots were stuck in the bottleneck of the femoral tunnel). A tie with Mersilene tape (Ethicon, Somerville, NJ) over a bone bridge for each tendon loop and an additional bioabsorbable interference screw were used for tibial fixation. Results The mean follow-up period was 38 months (range, 24 to 61 months). A significant improvement in knee function and symptoms was reported in most patients, as shown by improved Tegner scores, Lysholm knee scores, and International Knee Documentation Committee assessments (P
AB - Purpose To compare the clinical outcomes of femoral knot/press-fit anterior cruciate ligament (ACL) reconstruction with conventional techniques using femoral interference screws. Methods Among patients who underwent arthroscopic ACL reconstruction with hamstring autografts, 73 were treated with either a femoral knot/press-fit technique (40 patients, group A) or femoral interference screw fixation (33 patients, group B). The clinical results of the 2 groups were retrospectively compared. The inclusion criteria were primary ACL reconstruction in active patients. The exclusion criteria were fractures, multiligamentous injuries, patients undergoing revision, or patients with contralateral ACL-deficient knees. In the femoral knot/press-fit technique, semitendinosus and gracilis tendons were prepared as 2 loops with knots. After passage through a bottleneck femoral tunnel, the grafts were fixed with a press-fit method (grafts' knots were stuck in the bottleneck of the femoral tunnel). A tie with Mersilene tape (Ethicon, Somerville, NJ) over a bone bridge for each tendon loop and an additional bioabsorbable interference screw were used for tibial fixation. Results The mean follow-up period was 38 months (range, 24 to 61 months). A significant improvement in knee function and symptoms was reported in most patients, as shown by improved Tegner scores, Lysholm knee scores, and International Knee Documentation Committee assessments (P
UR - http://www.scopus.com/inward/record.url?scp=84903318051&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84903318051&partnerID=8YFLogxK
U2 - 10.1016/j.arthro.2014.02.041
DO - 10.1016/j.arthro.2014.02.041
M3 - Article
C2 - 24768467
AN - SCOPUS:84903318051
SN - 0749-8063
VL - 30
SP - 823
EP - 832
JO - Arthroscopy - Journal of Arthroscopic and Related Surgery
JF - Arthroscopy - Journal of Arthroscopic and Related Surgery
IS - 7
ER -