T1 - Assessment of mechanical characteristics of polyetheretherketone as orthodontic fixed lingual retainers
AU - Win, Pyi-Phyo
AU - Chen, De-Shing
AU - Sainbayar, Bolormaa
AU - Peng, Tzu-Yu
AU - Cheng, Hsin-Chung
N1 - Funding Information:
The authors thank Mr. Hung-Yi Chen (ARCH Dental Laboratory, Taipei, Taiwan) for technical assistance with manufacturing the specimens, and this study was supported in part by the College of Oral Medicine, Taipei Medical University, Taiwan ( TMUCOM202301 ).
Publisher Copyright:
© 2023 Association for Dental Sciences of the Republic of China
PY - 2023/10
Y1 - 2023/10
N2 - Background/purpose: Polyetheretherketone (PEEK) is known for its strength, flexibility, biocompatibility, and potential as a replacement for metals in dental appliances; however, uncertainty remains about the mechanical characteristics and dimensions of PEEK-made orthodontic fixed lingual retainers (FLRs). This study aimed to determine the optimal shape of PEEK-made orthodontic FLRs using the finite element method (FEM) and the three-point bending test (TPBT). Materials and methods: Seventy-five three-dimensional PEEK rod-shaped models were created, which included five thicknesses (0.4, 0.6, 0.8, 1.0, and 1.2 mm), five widths (0.7, 0.9, 1.1, 1.3, and 1.5 mm), and three cross-sectional shapes (rectangular, oval, and hemielliptical). A 0.9-mm (0.036-inch) stainless steel wire (SSW) was used as a control and the FEM was used to determine six optimal dimensions among the PEEK models. The selected models were then fabricated and subjected, along with the SSW, to the experimental TPBT to assess their mechanical responses against lingual and biting pressures. Results: The FEM analysis revealed that Von Mises stresses on the PEEK models decreased with an increase in width and thickness. Six optimal shapes of PEEK models were chosen based on acceptable lingual and biting stresses as well as patient comfort compared to the SSW. Furthermore, PEEK models showed significantly lower deformation during the 3.1-mm deflection test than did the SSW, while no notable differences were observed among different sizes of PEEK models. The hemielliptical PEEK model with a thickness of 1.0 mm and width of 1.5 mm was found to be mechanically robust enough to withstand lingual forces, while none of the PEEK models, including the SSW, were able to resist biting forces. Conclusion: Within the limitations of this in vitro study, PEEK-made orthodontic FLRs with a hemielliptical cross-sectional shape and a thickness-to-width ratio of 1.0:1.5 would be suitable for use as orthodontic FLRs.
AB - Background/purpose: Polyetheretherketone (PEEK) is known for its strength, flexibility, biocompatibility, and potential as a replacement for metals in dental appliances; however, uncertainty remains about the mechanical characteristics and dimensions of PEEK-made orthodontic fixed lingual retainers (FLRs). This study aimed to determine the optimal shape of PEEK-made orthodontic FLRs using the finite element method (FEM) and the three-point bending test (TPBT). Materials and methods: Seventy-five three-dimensional PEEK rod-shaped models were created, which included five thicknesses (0.4, 0.6, 0.8, 1.0, and 1.2 mm), five widths (0.7, 0.9, 1.1, 1.3, and 1.5 mm), and three cross-sectional shapes (rectangular, oval, and hemielliptical). A 0.9-mm (0.036-inch) stainless steel wire (SSW) was used as a control and the FEM was used to determine six optimal dimensions among the PEEK models. The selected models were then fabricated and subjected, along with the SSW, to the experimental TPBT to assess their mechanical responses against lingual and biting pressures. Results: The FEM analysis revealed that Von Mises stresses on the PEEK models decreased with an increase in width and thickness. Six optimal shapes of PEEK models were chosen based on acceptable lingual and biting stresses as well as patient comfort compared to the SSW. Furthermore, PEEK models showed significantly lower deformation during the 3.1-mm deflection test than did the SSW, while no notable differences were observed among different sizes of PEEK models. The hemielliptical PEEK model with a thickness of 1.0 mm and width of 1.5 mm was found to be mechanically robust enough to withstand lingual forces, while none of the PEEK models, including the SSW, were able to resist biting forces. Conclusion: Within the limitations of this in vitro study, PEEK-made orthodontic FLRs with a hemielliptical cross-sectional shape and a thickness-to-width ratio of 1.0:1.5 would be suitable for use as orthodontic FLRs.
KW - Bending test
KW - Fixed lingual retainer
KW - Orthodontic
KW - Polyetheretherketone
KW - Shape optimization
UR - http://www.scopus.com/inward/record.url?scp=85161495131&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85161495131&partnerID=8YFLogxK
U2 - 10.1016/j.jds.2023.05.026
DO - 10.1016/j.jds.2023.05.026
M3 - Article
SN - 1991-7902
VL - 18
SP - 1804
EP - 1811
JO - Journal of Dental Sciences
JF - Journal of Dental Sciences
IS - 4
ER -