Abstract
A model for the mechanism of the Gel permeation chromatographic separation of a polymer and a new calibration method have been developed, based on the exclusion of the polymer from the pores of the packing material. We propose that the calibration curve a plot of log (1—√K) versus log (molecular weight), where K is the elution volume coefficient, is close to linear over a K range of 0.15–0.85. We compare our procedure with that of Haller for various sets of data. Our procedure is generally better with lower standard deviations. When extrapolated, it gives a critical permeation size characteristic of the glass column packings.
Original language | English |
---|---|
Pages (from-to) | 55-59 |
Number of pages | 5 |
Journal | Journal of the Chinese Chemical Society |
Volume | 33 |
Issue number | 1 |
DOIs | |
Publication status | Published - Mar 1986 |
Externally published | Yes |
Keywords
- Fractionation of polymer
- Gel permeation chromatography
ASJC Scopus subject areas
- General Chemistry