T1 - A matrix-induced ion suppression method to normalize concentration in urinary metabolomics studies using flow injection analysis electrospray ionization mass spectrometry
AU - Chen, Guan yuan
AU - Liao, Hsiao Wei
AU - Tseng, Yufeng Jane
AU - Tsai, I-Lin
AU - Kuo, Ching Hua
N1 - Publisher Copyright:
© 2015 Elsevier B.V. All rights reserved.
PY - 2014/11/14
Y1 - 2014/11/14
N2 - Normalizing the total urine concentration is important for minimizing bias in urinary metabolomics analysis comparisons. In this study, we report a matrix-induced ion suppression (MIIS)-based method to normalize concentration using flow injection analysis coupled with electrospray ionization mass spectrometry (FIA-ESI-MS). An ion suppression indicator (ISI) was spiked into urine samples, and the intensity of the extracted ion chromatogram(EIC) for ISI in a urine matrix was subtracted by the EIC for a blank solution and used to calculate the extent to which the signal was reduced by the urine matrix. A series dilution of pooled urine samples was used to correlate the urine concentration and level of ion suppression for ISI. A regression equation was used to estimate the relative concentration of unknown urine samples. The MIIS method was validated for linearity, precision and accuracy.We obtained a good correlation using a quadratic regression model for 1- to 32-fold urine dilutions (R2 = 0.998). The reproducibility (n = 4) and intermediate precision (n = 3) were below 5% RSD, and the accuracy ranged from 97.15% to 102.10%. The established method was used to estimate the relative concentrations of 16 urine samples, and the resultswere compared with commonly used normalization methods. Pearson's correlation test was used to demonstrate that the MIIS method correlated highly with the creatinine and osmolarity methods; the correlation coefficients were 0.93 and 0.99, respectively. We successfully applied this method to a urinary metabolomics study on breast cancer. This study demonstrated the MIIS method is simple, accurate and can contribute to data integrity in urinary metabolomics studies.
AB - Normalizing the total urine concentration is important for minimizing bias in urinary metabolomics analysis comparisons. In this study, we report a matrix-induced ion suppression (MIIS)-based method to normalize concentration using flow injection analysis coupled with electrospray ionization mass spectrometry (FIA-ESI-MS). An ion suppression indicator (ISI) was spiked into urine samples, and the intensity of the extracted ion chromatogram(EIC) for ISI in a urine matrix was subtracted by the EIC for a blank solution and used to calculate the extent to which the signal was reduced by the urine matrix. A series dilution of pooled urine samples was used to correlate the urine concentration and level of ion suppression for ISI. A regression equation was used to estimate the relative concentration of unknown urine samples. The MIIS method was validated for linearity, precision and accuracy.We obtained a good correlation using a quadratic regression model for 1- to 32-fold urine dilutions (R2 = 0.998). The reproducibility (n = 4) and intermediate precision (n = 3) were below 5% RSD, and the accuracy ranged from 97.15% to 102.10%. The established method was used to estimate the relative concentrations of 16 urine samples, and the resultswere compared with commonly used normalization methods. Pearson's correlation test was used to demonstrate that the MIIS method correlated highly with the creatinine and osmolarity methods; the correlation coefficients were 0.93 and 0.99, respectively. We successfully applied this method to a urinary metabolomics study on breast cancer. This study demonstrated the MIIS method is simple, accurate and can contribute to data integrity in urinary metabolomics studies.
KW - Breast cancer
KW - Flow injection analysis-electrospray
KW - Induced ion suppression
KW - Ionization-mass spectrometry
KW - Matrix
KW - Normalization
KW - Urinary metabolomics
UR - http://www.scopus.com/inward/record.url?scp=84943160663&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84943160663&partnerID=8YFLogxK
U2 - 10.1016/j.aca.2015.01.022
DO - 10.1016/j.aca.2015.01.022
M3 - Article
C2 - 25732423
AN - SCOPUS:84943160663
SN - 0003-2670
VL - 864
SP - 21
EP - 29
JO - Analytica Chimica Acta
JF - Analytica Chimica Acta
ER -