加馬刀與電腦刀應用於動靜脈畸形治療之臨床評估比較與劑量差異分析

Translated title of the contribution: Clinical Evaluation and Dosimetric Comparison of Gamma Knife and Cyberknife Treatment Plans for Arteriovenous Malformations

Chun-Yuan Kuo, An-Cheng Shiau, Yu Kai Su, Chih Chieh Chang, Hsiao-Wei Yu, Sheng-Fang Huang, Li-Jhen Chen, Jia-Wei Lin, Jo-Ting Tsai

Research output: Contribution to journalArticlepeer-review

Abstract

Purpose: To analyze and compare the dose distribution characteristic of two radiosurgery treatment devices of Gamma Knife®(GK) and Cyber Knife®(CK), in treating arteriovenous malformations (AVMs) and the influence on their clinical application.Material and Method: Ten AVM patients treated with CK of prescribed dose of 20-25 Gy in single fraction were evaluated. Each treatment plan CT images including the contours of the target and the surrounding critical organs were exported and loaded into the GK treatment planning system. GK treatment plan using the same prescribed radiation dose were generated. Dosimetric comparison of the two treatment devices including the conformity, gradient and heterogeneity index, volume of brain tissue covered by 10 Gy and 12 Gy, maximum dose of brain stem and the beam on time. Paired Samples t-test was used to statistical analyze and compare the conformal and gradient index, the dose coverage volume of 10 Gy and 12 Gy in both plans for significance (p value)Result: The conformal index was 0.626 ± 0.106 and 0.795 ± 0.087 in GK and CK, respectively (p = 0.004). The gradient index was 3.082 ± 0.369 and 6.071 ± 1.698 in GK and CK, respectively (p = 0.001). The heterogeneity index was 0.723 ± 0.055 and 0.275 ± 0.045 in GK and CK, respectively. The difference of coverage volume of 10 Gy and 12 Gy were significant (p = 0.025 and 0.022, respectively). For the 3 cases with AVM location adjacent ωthe brainstem, the dose of 1 c.c. and maximum dose of brain stem in GK plan were less than CK. CK had better treatment efficiency due to shorter beam on time.Conclusion: Cyber Knife using inverse treatment planning similar to intensity modulated function had better dose conformity. Gamma Knife should have better normal brain tissue and critical organs protection due to sharp dose fall-off gradient.
Translated title of the contributionClinical Evaluation and Dosimetric Comparison of Gamma Knife and Cyberknife Treatment Plans for Arteriovenous Malformations
Original languageChinese (Traditional)
Pages (from-to)281-292
Number of pages12
Journal放射治療與腫瘤學
Volume20
Issue number4
DOIs
Publication statusPublished - 2013